Search results

  1. T

    UFH KW required per zone

    Hello, I wanted to know what the rule of thumb is per KW for a underfloor heating ring approx under 100m per zone. Bit like where the rule of thumb per rad is 1.5KW and 2/3KW for hot water.. Thanks
  2. T

    PERIMETER LASER ALARM

    Hi, I’m looking to upgrade my alarm system and I’m interested in arming the house whilst my family is inside. I would like something outside the windows like lasers between the two so if someone try to break in the alarms would go off. Any recommendations on any good reliable products you...
  3. T

    Noisy Honeywell Bypass

    Hi Guys, I've just turned on my UFH and i'm hearing a lot of noise from the Bypass vaule as if it leaking. Any ideas why this may be? wasn't an issue with when having the hot water and rads on. Thanks!
  4. T

    RGB LED Strip Lights

    Thanks guys i need the driver bit! Any ideas on what kind of cable i can use to extend this by 5m?
  5. T

    RGB LED Strip Lights

    Hello, I purchased a 5m led strip lights from LEDHUT and would like to fit them in my garden under a coping stones flower bed on either side. The strip light has 4 wires thin wires and I've purchased a led 12v transformer for 80w. I would like to fit the transformer inside the garage so would...
  6. T

    Ring Pro Door Bell

    Hello, I just had a ring pro fitted directly to a 24v transformer and a wireless chime, the issue is that it has a lag and at times the chime does not ring, I would like to wire a normal hardware chime. Could anyone advise how I could do this, I have a basic chime with a built in transformer...
  7. T

    Smart Alarm

    Thanks for your reply. So you are suggesting that I go all new with a new hybrid system which will be part hardwired and part radio? Can you please send me a link to one of these? Thanks
  8. T

    Smart Alarm

    It's a scantronic 9751 with a separate expander and speech dialer. 9 sensors 3 panic alarms 1 internal sounder 1 external sounder 1 door contact Currently the alarm it not active due to to refurbishment but the same one will be going back with new sensors and a new keypad as they got damaged...
  9. T

    Smart Alarm

    Hello I've already got a hardwired scantronic alarm system but it's not smart in the sense app controllable, also I would like to set the alarm whilst we are indoors but I have no contacts on the window entry points so it's not really possible. Any suggestions as to what I can do? Re-running...
  10. T

    Hikvision / Hilook IP Cameras

    Hello, In the past I've installed hikvision turret cameras for a few of my friend, I've now have another project but notices hikvision no longer sell their standard range to end users and instead have come out with a Hilook version which is cheaper. Does anyone know what these are like? The...
  11. T

    Porch Double Glazing

    Hello All, I currently have a porch with redlands 49 tiles on top, recently had new double glazing installed and they removed all the old hardwood timber frames and installed upvc. I've noticed they haven't installed any steel post for the colum and nothing on the top groove going across. The...
  12. T

    Porch Roof

    Hello All, I currently have a porch with redlands 49 tiles on top, recently had new double glazing installed and they removed all the old hardwood timber frames and installed upvc. I've noticed they haven't installed any steel post for the colum and nothing on the top groove going across. The...
  13. T

    Polyplumb Stainless Steel Using 16mm pex-Al Pipe

    Hello All, I've just ran my underfloor heating pipe using 16mm Pex-Al pipes and the fittings on the PB manifold are 15mm push fits, I was sold the 16mm to 15mm brass tail which seems to fit nicely but upon filling the system each one of the fittings leaked from the push fit side. I've open...
  14. T

    MC3 Cleaner

    Hello Chaps, i've just had a brand new valiant ecotec plus boiler installed with a manga clean. The house has never been flushed out and would like to use the MC3 cleaner on it. I've some chemicals can crack up joints on old pipe work so i just wanted some advise before I put this into the...
  15. T

    IR Extenders / HDMI Extenders with IR

    thanks for the advice! Many thanks
  16. T

    IR Extenders / HDMI Extenders with IR

    Hello, I am having some works done in my house and am planning of removing all my AV Kit (Amp / Blue-ray/ Sky box) from the under cabinet and have it placed into a storage cupboard which is 5 meters away from the TV itself. What are my best options here as some of the IR extenders I've seen...
  17. T

    New Zone Valve

    Sealed
  18. T

    New Zone Valve

    Sounded in-corrected to me too... If he was to place the pump downstairs near the boiler would that be sufficient? probs mean doing some wiring change... Thanks!
  19. T

    New Zone Valve

    Hi, I am having some house works done and have decided to add another zone for the downstairs radiators so they can be controlled separately. Currently the boiler in on the ground floor and the rest of the plumbing is in the loft, the plumber has converted the 3 port valve into 2 sets of 2...
  20. T

    polypipe UFH Manifold

    Hello Chaps, I'm after a Polypipe UFH manifold and would like to use 16mm pipe as i have quite a bit left over. I hear the brass unit will be disconnected very soon, the stainless steel ones are 15mm push fit connections. Is it possible to use some sort of an adapter and remove the pushfit...
Back