Search results

  1. P

    taking spur outside

    parent want a new socket on other side of bay window,concrete floors,not long redecorated so up and down walls is a no no,is there any problem taking cable through back of existing ring socket to outside,running swa cable clipped to wall and then back in to new socket. or anyone got any other...
  2. P

    ceiling fan and gas.

    thanks pannierstan, so should the fitter have done this test when he saw the fan, and any idea why an isolation switch should be fitted to fan (seperate from on/off switch)
  3. P

    ceiling fan and gas.

    a mate has had the gas fitter round to look his gas fire,the fitter has seen a ceiling fan in the room and told my mate he has to have his fire isolated,or (this is the part i can't understand)have an isolation switch fitted to the fan? i can't think why an isolation switch would make it safer...
  4. P

    best procedure for finding fault

    thanks spark ,thats the sort or info i was hoping for
  5. P

    best procedure for finding fault

    i have test equipment,have you read my previous posts?,i have been asking for the correct procedure.thanks
  6. P

    best procedure for finding fault

    i switched the mcb to the circuit off before disconnecting, and was confident with what i was doing. i can even cross roads without waiting for a beeping sound telling me it,s safe to cross.god i hope the regulation police are'nt reading this. anyway can anyone tell me the best way to...
  7. P

    best procedure for finding fault

    only the four fluorescents and two spots on the circuit, did,nt do ins resistance due to the 14v on the earth,and could'nt turn off supply to the consumer to as the other circuits were in use,having another go tomorrow night.so what would be the best way to proceed
  8. P

    best procedure for finding fault

    mate has a small unit and main rcd (not the mcb) trips when lights switched on.only two light and ring fuses in consumer there are four fluorescents (2 are no longer used but were still connected) and two spots on the circuit(a second light circuit is ok).i have disconnected all the lights from...
  9. P

    downlighters and insulation

    thanks fireman,but i don't need fire hoods they just seal the hole if there is a fire and i would still have the same problem of not being able to cover the lights with loft insulation,i am looking for some sort of tube to take the heat from the lamps through the insulation. kier i have looked...
  10. P

    downlighters and insulation

    downlighters in an upstairs room with loft insulation above, i know i can't put the insulation back over the lights due to heat, and i can't find anything commercialy available that will allow the heat to escape through the insulation.so what is the answer.
  11. P

    5 ft of plastic

    mains water pipe from stopcock in kitchen is copper for about 2ft then changes to plastic for about 15ft,then back to copper through rest of house, where should it be bonded ?
  12. P

    rewireable main fuses?

    a mate is fitting a shower to a house he has just bought 8.5kw.and has noticed he has 2 main fuses where it comes into the house. one on the live and one on the neutral and they look like rewireable,it also says 30a on the holders is this ok? or can he have them uprated
  13. P

    whirlpool flashing

    problem with a philips whirlpool awm 6145 , put it on any cycle and press the power switch on, the pump starts for about 15 sec then the door closed light and the power switch backlight start to flash and the machine won't do anything from then on. any ideas what fault the flashing lights...
  14. P

    earthing boiler

    thanks john,so what happens connections are plastic
  15. P

    earthing boiler

    does a boiler in a kitchen need the pipes connecting together with earthing cable.if yes,then are just the pipes on the boiler linked together or is the cable then taken back to the consumer/ main cold water pipe. The incoming water and gas are bonded. and what if the cold/hot feed and return...
  16. P

    rcd or not

    can you settle an argument? kitchen and conservatory being rewired.oldish consumer unit with mcbs but no rcd main switch, as the consumerm is not going to be replaced can the new ring be put back into the mcb or would a seperate rcd have to be fitted due to the sockets being accessable from...
  17. P

    fire regs

    thanks for the replys,but does everybody fit them?,according to the article if there was a fire and the downlighters were'nt fitted with the hoods the penaltys were severe,jail and something like 20 grand fine so if you are a leccy do you take the chance? and how many of your customers would be...
  18. P

    fire regs

    i wanted to fit some downlighters into a room downstairs and one upstairs, so i was browsing on the web and came across an article that stated,houses built after jan 2003 have to have a firehood fitted above each light due to fire and sound proofing regulations. so i made a visit to an...
  19. P

    Past Papers C&G 2361 pt 2 Electrical Installation.

    if you are offered any past papers make sure they are recent,i sat my exam 2 yrs ago and worked on past papers for months. they changed the exam papers completly that year and i just scraped through.
Back
Top