  1. sparkymarka

    Reuse existing circuit

    That fire alarm is a loop it starts at the fire panel and ends at the panel …everything inc sounders plus other devices are on that loop ( there may be a separate bell circuit aswell which may be a normal EOL circuit …. You need to make sure everything is removed or it may go with a bang if you...
  2. sparkymarka

    A dead Honeywell Galaxy 96 dimension panel.

    You need to speak to galaxy guy …
  3. sparkymarka

    Texecom Connect Notifications

    I think a look at the log in the panel ( from user menu ) may shed some light on it
  4. sparkymarka

    Texecom Connect Notifications

    It’s not just a yes or no ….as not knowing what program options have been set there could be multiple reasons as to what you have described ….there are probably hundreds of variables on the Texecom depending of programming options
  5. sparkymarka

    Texecom Connect Notifications

    Sounds like it didn’t go to full alarm …
  6. sparkymarka

    Texecom Connect Notifications

    I would …. Part set then activate a guard zone and see what happens as it may be the case of a pre alarm and it was turned off before a full activation ? Did you have to reset the alarm ?
  7. sparkymarka

    Texecom Connect Notifications

    Was it part armed ?
  8. sparkymarka

    Pyronix Enforcer 76 and Masking error on two PIRs wired to single zone

    I take there wasn’t spare cores to split down the two detectors
  9. sparkymarka

    Pyronix Enforcer 76 and Masking error on two PIRs wired to single zone

    I think that is correct as I had the same issues on a job …that was the answer from tech support….
  10. sparkymarka

    Sounder Battery

    I would spend the money on someone who knows what they are doing and can fault find in a logical process …. as I think you will end up going round in circles …
  11. sparkymarka

    Sounder Battery

    Theirs is no difference whether it’s powered by battery or mains ….unless there is something else connected to,that mains supply ..that only runs off 240 volts …
  12. sparkymarka

    Sounder Battery

    You have no idea what you are doing !
  13. sparkymarka

    Watching CCTV remotely on my Hikvision system

    It’s allready on the network via an app ….say no more …
  14. sparkymarka

    'Isolator'/switch for smoke etc. alarms?

    That type has a rechargeable lithium battery
  15. sparkymarka

    'Isolator'/switch for smoke etc. alarms?

    They never last 10 years …..
  16. sparkymarka

    Texecom D20 PIR Tamper Issue

    Does the faulty pir light up ?
  17. sparkymarka

    'Isolator'/switch for smoke etc. alarms?

    FFS …Smoke alarms bleep when the back up battery is getting low …..for weeks even months ….i think someone would notice …anyway if you fit the AICO smokes all you need to do is release the faulty one and slide in a new unit …no need to isolate anything