  1. J

    quick gas capacity question

    Hi, im not doing any work here, just looking at feasibility. How many kW can I get from a 1" tapping at 70mbar for natural gas. The supply is more than big enough, and again at 3/4" or can anyone point me to how to work it out Thanks
  2. J

    flexible gas joints

    im not doing anything, just curious. how would you take a supply from an existing tapping where the building flexes by, say, half an inch? can you use an annoconda like at a meter, or one of the EPDM bellows? Do regs allow this, or does it all have to be rigid pipe?
  3. J

    direct fired gas water heater

    does anyone have any experience with them? im looking to have a replacement installed. its replacing two 300l direct electric calorifiers that lack in capacity, id like to have a single calorifier, gas fired, about 800l stored, room sealed, pumped return with a half decent recovery time...
  4. J

    Calorifiers venting

    Hi, I have two 300l direct calorifiers installed together as a pair for domestic hot water. One is a heatrae sadiaa, the other isnt. Im getting water issuing from the drain outside, so I reduced the length of the pipe from the T&PR valve, and it was dry on both, and then the one on the first...
  5. J

    Gas plumbed as a ring

    is it within regs to install gas as a ring? Im just looking at an existing installation, not installing or altering or anything, just curious. basically, its a figure 8 with the supply fed in at one corner, 35mbar 2"
  6. J

    Pipe Sizes

    I must be having a thick spell. I cant get my head around some pipe size calculations. I have a studio, 50mm insulation timber framed building that I am going to extend my existing boiler to cover on a separate zone. The pipe run to the furthest radiator is about 14m For reasons of space...
  7. J

    On another forum

    Browsing the internet, i came across this current discussion http://www.sheffieldforum.co.uk/showthread.php?t=1103533 what do we think?
  8. J

    Damp in house

    Hi, I have a raft built house, 1950s brick construction on clay soil, floorboards and about 12" void between the floorboards and concrete raft. The damp course is 2 courses above ground level at least all the way round, airbricks are fitted all the way round too. I have problems with...
  9. J

    Stop tap requirements

    Hi, does anyone know the requirements or know a link to the requirements that the main stop tap needs to meet, non-return valves etc? I have had a look but cant find anything official thanks :)
  10. J

    Washer dryer steaming excessively

    Hi, i have a Bosch washer dryer, when its drying, it recently has started to steam excessively through the soap drawer to the point that the floor in front is wet, any ideas what i should check? thanks :)
  11. J

    Electricity usage was 6kwh now 46kwh per day

    I seem to have suddenly started using vast amounts of electricity as per readings taken over the last few days. Today, i turned the main switch off and the Ampy Metering 5235A continued to flash 5 times a minute, my clamp on ammeter showing 0 amps the base load for the house is around 1.5a...
  12. J

    dusk to dawn outside lighting

    My parents currently have about a dozen of those glass bulkheads on the outside of their house, with either 60 or 100w gls lamps in, along with some 150w floodlights, on a PIR. as they are getting on a bit, and the house is in the countryside, im worried about them falling on their way to the...
  13. J

    Dorman Smith Loadmaster MCB

    Hi, I need to replace a mcb in a Loadmaster d/b It seems that 3p breakers smaller than 40a arent available anymore. Does anyone know if replacement breakers were made that will fit in this board? Thanks
  14. J

    Disaster preparing painted walls

    Hi, Im decorating my bedroom for the second time since i moved in. Some parts of the wall have blistered, i think this was damp as the house was left empty for a few years beforehand. I have scraped this off no problem but now on the other walls, where im filling using a lightweight...
  15. J

    Saunier Duval F30E Leaking

    Hi, I have got a Saunier Duval F30E boiler and it has sprung a leak on a plastic part between the heat exchanger and the DHW outlet. I cant see what part it is in the instructions but think it might be the three way valve. Is anyone able to identify the part for me? Thanks
  16. J

    Bosch WVT1260 not drying

    Hi, Today my WVT1260GB has developed a fault in the drying cycle. The clothes are not drying or even warming. The machine doesnt seem to be making as much noise as i remember, a fan not on maybe? There are no error messages on the display Any ideas? thanks
  17. J

    Metal Halide High-Bays

    Hi, I am trying to buy MH lamps for some fittings at work. I have obviously confused the local supplier because we currently have high bay fittings with tubular enclosed rated lamps fitted without safety glasses. The lamp is an Edison EDHPIT400, so basically, I need an open rated version...
  18. J

    joining cables in dado trunking

    Hi, What do you reckon the best way to joint cables in dado trunking is? For singles and T+E. Crimps? Thanks
  19. J

    BT Titan and Agile

    Hi, Im having a new alarm fitted and Im slightly confused about the difference between a BT Redcare Secure Titan 2 and a BT Agile. Anyone fitted one or know? Thanks
  20. J

    Labelling pipework

    Hi, I have a myriad of copper pipework 54mm and down. I wanted to put traffolyte labels on them so I know what they do before I shut half the place down! What do the pros do when fixing rigid labels onto pipework? Is there a bracket or something that you buy? Thanks