Search results

  1. R

    Switched live for New Condensing system boiler

    Thanx for that Picasso, ok then, here is my revised wiring center set up, would you be good enough to have a look at to see if its correct?.
  2. Untitled

    Untitled

  3. R

    Switched live for New Condensing system boiler

    Hi picasso, its an Alpha CD18S
  4. R

    Switched live for New Condensing system boiler

    I am about to have my new Alpha condensing system boiler commissioned by a registered fitter, the boiler has its own pump but no time clock, I need to provide 2 lives, one permanent and one switched, the first is not an issue, its the switched live. The current system is a Y plan with the...
  5. Untitled

    Untitled

  6. Heating

    Heating

    pics
  7. R

    Switched live for New Condensing system boiler

    Thanx Tony, I am not commissioning the boiler, the guy who is Gas Safe, I take it you from within the wiring center?. Rich
  8. R

    Switched live for New Condensing system boiler

    I am at the stage of my new extension whereby I now need to commission my new Alpha condensing system boiler, this boiler, with integral pump, is situated in the new utility room adjacent to the kitchen where my original boiler is. Original system is Y plan fully pumped, boiler is Halstead, cyl...
  9. R

    kitchen extension creates L shaped room

    Evening all, i have just built a rear extension, which now creates a new L shaped kitchen, from the original hallway doorway you will now see the new french doors of the new extension, the dividing wall not yet removed. I now need to tile over the underfloor heating in the new kitchen area...
  10. R

    Building off rear semi centre pillar on extension to rear

    Thanx for that freddie, bloody architects, dont ya luv em..............not.
  11. R

    Building off rear semi centre pillar on extension to rear

    THe boundary line between the house is exactly the centre of the pillar
  12. R

    Building off rear semi centre pillar on extension to rear

    I am currently starting a new extension to the rear of my property which had plans passed in 2007, the drawings from the architect show the rear wall coming off the centre of the rear pillar to a depth of 3 metres from the house, as is normal for for semi detached properties, now since the...
  13. R

    Regularisation Application !!!

    The last response from Freddie has asked what has the car port got to do with it??. Ok let me explain, back in 2007 i submitted my own plans along with the fee's for both planning and building control for a car port, the planning permission was granted and I then did the trench for the...
  14. R

    Regularisation Application !!!

    ok, as the work we have already done could be used to complete the carport, and as there are no works yet to the rear could i complete the car port as i have already paid for building regs on it, and then apply a fresh application for building control the remaining build, this would negate a...
  15. R

    Regularisation Application !!!

    Firstly thanx to all for your input, I feel i should explain a bit more about the project, the project commenced in 2007 after planning approval and it was going to be a do as can afford to do, to date their are footing a metre deep alondside the house of 12.4 metres, these have already been...
  16. R

    Regularisation Application !!!

    Due to complete and utter cock up by the architect in not applying for building control, only planning. I visited my local council offices in order to submit the required form and fees, just to put you in the picture the project is for a side extension of 2 storeys and single storey to the rear...
  17. R

    Wickes 40-50 boiler problem????

    Hi everyone, got a problem with our wickes 40-50 boiler, when the boiler fire up and either the water or heating stats trigger the shut down, the pilot goes out too, yesterday left the boiler stat at zero, re-lit the pilot and came back home to find the pilot still lit!, ran the system last...
Back
Top