  1. B

    Changing a 16th edition CU

    I've been asked to finish a job that was started a few years ago the only problem is when the job was started the 16th edition regs were in place, So the consumer units that were fitted at this time are also only up to 16th edition regs and so some of the circuits have no rcd protection. My idea...
  2. B

    Castlec MCB

    I've got to go to a job tomorrow and and i no that the mcb's being used are Castlec. I'm not sure what make the CU is but does anyone know if there are any other mcb's that are the same design and so will it fit into the same CU?
  3. B

    Towel rail ip 21

    I've recently done a periodic report for a friend of mine who is selling his house. When i was looking round the bathroom i noticed that the electrician who had previously done the work had installed a towel rail in zone 2 of the bathroom, which originaly i thought would be ok as the switch for...
  4. B

    Broken immersion heater

    My mate has asked me to go round his house and see whats wrong with his immersion heater, he said he's changed the thermostat on it but that only lasted a couple of days and now its stopped working again. I haven't done anything with an immersion heater for years and so can't remeber much about...
  5. B

    Fire hoods above downlights

    Apologise if this has been asked before, but i recently ordered some fire rated 12v downlights for the bathroom but when i received them i noticed that there is no in built hood on them like the non bathroom rated ones. Does this mean that i have to add my own hood or, like a technical advice...
  6. B

    Obsolete RCBO's

    I've been asked to extend a lighting circuit for someone, which will obviously mean putting the lighting circuit onto an RCBO. The only problem is the consumer unit is a square d qwikline, but the older version, and when i rang the wholesaler they told me that the older version of this make is...
  7. B

    Fault on existing lighting circuit

    I've recently been called to a fault on a lighting circuit in a property, when asked if the occupier had done anything differently he told me that all he had done was change the lamps to the eco friendly ones. I then disconnected all the lamps and when i then tested the circuit the only time...
  8. B

    Extending cables underfloor

    I'm at a job where i've been asked to extend same cables, now unfortunatly this must be done under the floor. I know that Junction boxes are now not allowed, and i would use crimps in a choc box, but recently i found out that apprently crimps aren't very good on solid cables and only work well...
  9. B

    Overhead cable

    I need to run some cable between 2 sheds to supply a consumer unit, what would be the cheapest and safest way of doing this? Preferably over head.
  10. B

    Heater in wet room

    I've recently been asked to fit a heater in a wet room now i know that there is only a zone 0 and 1 in a wet room which extends to 1.2m from a fixed shower haed (on site guide page 72) but when the shower head is not fixed i believe the distance then goes to 3m from the shower head position. The...
  11. B

    Connecting a forklift charger

    I've been asked to connect a forklift charger in a warehouse, so i rang up the supplier to find out what size rcbo to use and he told me to use a 50 amp, when i told him that the cable going into the charger was 4mm2 sy cable he told me it had been tampered with and that a 6mm2 sy cable should...
  12. B

    Consumer unit change

    I'e recently changed a consumer unit at the requet of a customer. Before doing it i did a insulation resistance test on the circuits and found them to be within the regs. However after i have changed the board i then did a full pir and found the circuits to be in a poor condition i.e. light...
  13. B

    Position of consumer unit

    I've recently wired for a CU at a house but then when i went back to the house the builder told me the kitchen plan had changed and that the sink was closer to the CU that i had expected. It is still 1metre from the nearest edge of the sink to the nearest edge of the CU. Is this still allowed?
  14. B

    Cables in conduit

    I've recently been asked to second fix a house that was already first fixed. The switch by the door is a 6 gang switch and on a stone wall, so the owners have asked for the cables to be run in conduit down the wall. Is it possible then to put 3 x 1.5mm twin and earth cables and a 1.0 mm 3 core...
  15. B

    Circuits tripping after consumer unit change.

    I've recently changed a consumer unit at a persons house and when i turned it on it began tripping the rcd. So now i've taken out the main rcd and moved them onto rcbo's and told the owner that i will sort out the circuits that are tripping. Now i know that with the current regs everything must...
  16. B

    Zs value and loose connection

    If you have a zs value that is within the allowed regulation is it still possible to have a loose connection? Sorry about some starting so many threads. I just worry loads. :(
  17. B

    Running swa in same trench as oil line.

    First of all i've already posted 2 new threads on this forum and have had a good informative response on both so thank you all who posted, really nice to no there are people out there so willing to help others. Second thing and my main point i've been asked by a builder to run an swa to a...
  18. B

    High zs on shwoer circuit

    I've recently installed a shower circuit for someone but when i come to test i can't seem to get the zs value for my showere below 1.79, which i no is high, the shower is on an rcbo i just need to no what i can do to get the value down and why this could be happening.
  19. B

    Neutral to Earth fault through Edison screw lamp?

    Iv'e recently been doing the electrics for a new bathroam have made sure everything is on rcbo's. The main problem i have is that the old electrics are in a very bad condition and the lighting circuit for the bathroom area was showing up a neutral to earth fault so after looking in the attic for...