  1. Rampage77

    Remeha Avanta Plus Combi 28C Problem...

    was it the same fault code, was it an intermittent fault, these are things that also need to be taken into consideration. Did it work ok for a while between gas valve fitted and then pcb?
  2. Rampage77

    Remeha Avanta Plus Combi 28C Problem...

    I wouldnt be paying for parts that have been fitted and the appliance still not working, but the mark up on parts is part of being a business.
  3. Rampage77

    Help! DS40 has turned my HW green or brown!

    As stated above if the coil in the cylinder was faulty water would go from HW to the CH system not the other way round due to the HW cold feed tank being higher.
  4. Rampage77

    GLOW WORM MICRON 50FF - ONGOING NIGHTMARE! Help?

    Have you checked the pump, the boiler may be coming on for a short time warms up then shuts off because the pump is not working. Also you could have zone valves on the system that are not opening causing the same situation. Do you have hot water in the cylinder? If so it could be a faulty 3...
  5. Rampage77

    Help identifying a boiler

    BIASI or Ideal Mini. Same boiler different badge.
  6. Rampage77

    HUMMING SOUND

    Lost dildo...... is that one of the indiana jones movies?
  7. Rampage77

    Replacing Room Thermostat

    You will need to wire the 'wireless' receiver into the wiring centre, normally located in the airing cupboard, then you can put the wireless part of the roomstat in the room you wanted to, (normally hallway)
  8. Rampage77

    im in my pants trying to swap a thermo shower tap

    I do all my jobs just in my pants, my customers are not happy about the situation.
  9. Rampage77

    boiler "cycling" and tripping out after rad removal and new pump

    Tripping out at 38 I would still go with my first post of pump wrong way. I hope it is this as it's an easy fix to the problem for you.
  10. Rampage77

    boiler "cycling" and tripping out after rad removal and new pump

    I would say that either you have put the pump the incorrect way round or you still have an airlock in the pipe work. Bleeding the radiators doesn't solve this, check for any air vents on the pipe work in the airing cupboard etc. It's a case o persisting with it, add a little more pressure than...
  11. Rampage77

    What certifications does an oil boiler fitter require?

    The installer could of installed it and got it signed off by another OFTEC registered company.
  12. Rampage77

    What certifications does an oil boiler fitter require?

    I 'think' you have to be OFTEC registered to install an oil boiler and tank, but not if you are just servicing or repairing.
  13. Rampage77

    Is this Asbestos?

    Asbestos is asbestos what ever colour it's named, will still do the same damage.
  14. Rampage77

    Why does my boilers pressure keep changing?

    If that's not passing then you have a faulty DHW heat exchanger, you will probably need a gas engineer for that.
  15. Rampage77

    Wondered if someone could help diagnose my boiler?

    Glad its all sorted, Happy days :)
  16. Rampage77

    New central heating pump not working & pipes making strange noises HELP

    All the people on here are happy to help, but you have come into a forum which is full of plumbers and basically said that the plumber is ripping you off. And now you want them to help you.........what sort of response was you expecting? We dont know what area of the UK you are from, but the...
  17. Rampage77

    Wondered if someone could help diagnose my boiler?

    It could of lost pressure due to the system settling down after the works been carried out, or you may have a small leak somewhere. Check the relief pipe that terminates outside for any signs of water. It wouldn't harm to add more inhibitor but I would wait until you're sure the system holds it...
  18. Rampage77

    Wondered if someone could help diagnose my boiler?

    Keep an eye on the pressure gauge over the next few days, if when the heatings on the pressure remains below or around 2 bar then the vessel is ok. If the pressure starts going nearer 3 bar when in use I would check the pressure in the vessel again. If it has lost pressure then I would say it's...
  19. Rampage77

    Boiler heating not firing up when Drayton SCR green light clicks on

    That will never work, you need the front part of the digistat
  20. Rampage77

    Only shower hot water fluctuates; boiler turns on & off often

    Chances are it will be the secondary heat exchanger blocked ('normally' is this with your symptoms)