Search results

  1. T

    Water heaters

    thanks for the reply, yes I see your point about the bath but what about over the sink in the bathroom?
  2. T

    Water heaters

    My grandad has moved from his home into a care home due to old age and not being able to look after himself properly, his bungalow does not have any hot water or heating. This is a hypothetical question: The cheapest way to install hot water would be via a water heater, but if you put a...
  3. T

    Capping

    chases ? I thought the idea of capping was that you dont have to chase it in, just nail straigt to the wall and the plaster covers it ??
  4. T

    How to skim a long wall and ceiling?

    what does that mean moderator 4?
  5. T

    How to skim a long wall and ceiling?

    excuse me thats not spam, thats information relating to this topic, if it was spam then I would be blasting the forum with url's This is a 24 page Ebook teaching you the basics on plastering, I thought it would be useful on this forum
  6. T

    How to skim a long wall and ceiling?

    hey my post got deleted, maybe cos it was linking to another forum, however it was relevent to the post Click Here
  7. T

    Repair or replace 9 year old system boiler?

    pay the hundred pound get it fixed then get it covered by british gas, £20 pound a month will cover all your rads, controls and boiler
  8. T

    RCD Testing

    When RCD testing you test at different values So you'd test at x0.5, x1 and x5 correct? at x 0.5 the rcd should not trip at x 1 the rcd should trip in less the 200ms at x 5 the rcd should trip in less then 40 ms this is from memory as I dont have my osg on me until thursday can...
  9. T

    Quiz of the week

    where's the cpc?
  10. T

    Testing

    ok mate will have a look when I go to college
  11. T

    Testing

    Can someone confirm to measure zs on a ring final circuit you would split the ring at the consumer unit, put one end in connector block and using a ppropriate meter measure the other end? And the same with r1 + r2, join live to cpc on one end measure the other, then join neutral to cpc and...
  12. T

    Time Switch

    definately better to ask, there's been some harsh comments on here tonight, can we take a moment to calm down 8)
  13. T

    Photos as threatened

    what a mess!
  14. T

    Photos as threatened

    woooow! On the second picture I see 2 neutrals connected but one of them seems to be cut off or maybe you did some photo editing?
  15. T

    A Couple Of Easy Questions

    thanks for your comments, I take all your advice on board and will note the cables will pass through conduit between the sheds and the lighting will be fed via an unswitched fused spur (3A) I will speak to the college, but Im doing distance learning, so everything is much harder
  16. T

    A Couple Of Easy Questions

    thanks for your reply, yes the supply is adequate I was more after yes its ok to feed lights via a unswitched fused spur or no thats wrong?
  17. T

    A Couple Of Easy Questions

    I was just asking in general if what I was putting down would be acceptable or not, Im not asking for the answers just some pointers. Edit: just a thought would I be better off installing a piece of tube to protect the cables where they span accross the air? As for the bonding its...
  18. T

    A Couple Of Easy Questions

    Im doing some theory work for college and just want to run a couple of things by you guys if you dont mind:- In Mr. Jones' house I need to add some lighting and power into a new shed, there is an existing shed about 500mm, what I was going to write down was:- The picture shows the existing...
  19. T

    Bonding

    Hi guys I was just wondering what should you bond as good practice and what is a requirement:- This is what I thought should be bonded:- Gas Pipes - Main Bond near meter Water Pipes - Main Bond where it enters building Metal Kitchen Sink - Good practice but not requirement Kitchen...
Back