Search results

  1. A

    boiler wireless thermostat

    Same happens to me when I carry those biscuits from Aldi in my Tranny! I don't have a clue what wireless receiver the OP was talking about though! Nope! Crystal ball cream crackered again!
  2. A

    boiler wireless thermostat

    Your very perceptive aren't you?
  3. A

    boiler wireless thermostat

    Was it a Ford Transit and the biscuits shortbread from Aldi for on £2.99 in the sale?
  4. A

    Dripping Vaillant Sine 18 T3WF H

    Thats some plumbers way of saying :- "Sorry mate I don't want the job" You can also read into it one of the following 1. "I haven't got a clue but I know if I do get this job I will be stuck on it for days while I fathom it out" 2. "I see a potential domino effect here and whatever I touch...
  5. A

    Plumber or builder?

    Please translate into english the word 'RONES' Worth getting a plumber round if just for an opinion, it could be an unsealed trap or something obvious like an untrapped washing machine. A good plumber would sniff it out where most builders wouldnt have a clue. Your deeds may have a plan of...
  6. A

    Powermax 155 leaky blending valve

    If you managed to replace it I am sure you could manage to drain it off and get some PTFE tape round the threads
  7. A

    Worth repairing pressure vessel on Vokera Linea Plus?

    LOL :lol: :lol: I reckon Tony was thinking of the Linea Max HE
  8. A

    Mum scammed by heating engineer or not?

    I'm curious as to the make and model of the boiler. Somewhere in the trading standards laws is a part that says in most cases estimates must be accurate to within 10%
  9. A

    Is this a DIYnot virus?

    It happens as I move around the pages in this and my alter ego identity.;) If its any help I mainly use firefox and although it could happen on IE I cant say I've noticed it on the few occasions I have used it. Unfortunately I cant tell you what ads are on as I use a script blocker to stop...
  10. A

    Water cool in the morning

    When the stove temp is 46ºC it will still be circulating and taking your hot water down to that temperature. Could you alter this to say 60 and see how it goes ? Highly likely. Although I suspect it is whats known as one pipe circulation basically the single highest pipe acts as a heat emitter...
  11. A

    Water cool in the morning

    If there was a fault/ design error and a pump was still running for a long time after the solid fuel fire had died down then hot water could be circulated back to the stove where it could lose its heat in between. Making sure a pump doesn't run in such a way would be a good plan and...
  12. A

    Is this a DIYnot virus?

    3 different puters here. 2 of them come up with a virus when I open new pages ie. clicking on a link for a topic in the forum. Antivir is the software thats finding it. It says something like html.crypted.gen File is always in temp internet files and ends ... \eas or \eas(1) \eas(2) etc...
  13. A

    Thorn M44/54C boiler

    Gas is expensive these days. Use it sparingly. Keep your boiler stat as low as you can get away with. Im sure that boiler is range rated ie you can set it to different outputs as stated. A manometer and corgi guy are needed. Fit TRVs, Comtrols and insulation. Save money! Your pump needs to...
  14. A

    Yet another Vaillant problem - VCW 242 and lack of hot water

    Excuse my attention span at this hour of the morning but I think you may have overlooked the possibilty of a partially blocked secondary heat exchanger. Is it the old black box or the newer sardine tin? Whatever it might just be full of crud
  15. A

    any specs for biasi m90e 32s please

    Most of them are available either on the manufacturers website or by emailing them. Heres a bit of a rundown on whats what. Harder ones to get hold of are Heatline Vokera and Vaillant, Ravenheat have most of them on their website but the 820/20t Is like rocking horse poo although you can get...
  16. A

    Dripping Auto Air Vent Valve

    I took the liberty of posting your pic so others could see it. If it was This type you wouldnt need to drain the system. :cry: ...... Might be worth investing in some pipe freezer to save draining off and clearing any airlocks later :idea:
  17. A

    Ferroli Modena 102 - Electircal problem?

    Terminals 1 and 2 are 230V so don't forget to turn the power off. I think its 3 and 5 that the other two wires go to. Strip back about 12mm of casing from both ends of a short [say75mm] piece of wire. Remove spade 3 and 5 and push the wire through the hole in each lug and/or replace each...
  18. A

    Electric instantaneous water heater and shower advice

    Just my opinion but here goes. Nat gas is best but £16k makes it not viable. Excluding the increase in the value of the property I reckon it will take 30 years to get your money back at best. Go for oil if you can afford it and may I suggest a HRM wallstar . This will be a better solution...
  19. A

    multikwik connector too large for cast iron pipe

    Multikwik do them in different sizes. I have always managed to get by with them but as you say this size isn't listed so try McAlpine or Hepworth. As a worst case scenario you could always go back to the next joint in the soil pipe and fit a caulking bush
  20. A

    Cold Radiator

    Have you extended a one pipe system by any chance? If so the 'ring circuit should be continued so that it runs below the new rad position. Apart from that it will likely be down to a blockage of some sort as Softus is implying