  1. J

    Anyone know of a boiler that will run on Methane?

    About 25 years ago I fitted a boiler at a sewage treatment works,this had a nu-way burner designed for natural gas. After some advise from nu-way and a bit of trial and error it ran very well on the methane harvested directly from the works.
  2. J

    Electro-Oil AB Manual

    There is nothing wrong with the O/P playing with his own boiler, the problem is the oftec "training" and registration procedure, there are to many people posting on various forums asking basic or daft questions, these people all claim a full set of oftec tickets. I am angry at oftec and the...
  3. J

    Electro-Oil AB Manual

    OFTEC is now a joke and posts like the above prove it.
  4. J

    Grandee Heating World combination boiler

    Intermitent faults are the worst, can you tell us what has been replaced so far ?. Is the tank lower or higher than the boiler ?.
  5. J

    Riello oil burner problem

    Anyone with their own swimming pool can afford to pay to get this fixed by a competent service engineer .
  6. J

    reillo oil burner no spark

    Remove the old electrode block and check for tracking to the nozzle holder. was the blast tube wet ?, if it was dry than look at faulty coil.
  7. J

    Oil Flow useage Meters

    Kent oil meters are a good one, we fitted a few years ago and have never had any problems with them.
  8. J

    32 second oil ?

    Myson is the boiler make, what is the model ?, mectron is the burner !. 28 and 35 are the normal grades of fuel, you can only burn 35 at high level (flue) and in a non condensing boiler. Look for a new "boiler man" as this is basic stuff that anyone competent should know.
  9. J

    EOGB Burner with intermittent lock out

    Duff coils on new pumps do happen !
  10. J

    Retrofit anti-cycle control?

    do you have a bypass? is the system balanced properly?.
  11. J

    EOGB Burner with intermittent lock out

    Attend site fist thing in the morning after its locked out, remove burner and look at blast tube, if its wet(oil) replace EBI, if its dry change the coil. These are the 2 most common faults on a sterling for the problem you describe.
  12. J

    Oil combi versus system

    Combis are expensive to maintain, my advise is go for a non system boiler and fit a separate sealed system pack, s-plan and unvented cylinder.
  13. J

    Grundfos Pump Plan valves sticking

    I would fit the check valves on the flows coming out of the pump, within the first foot or so if practical. What do you think of the warmflow combi ?, I have only worked on their regular and condensing kit which was straightforward enough.
  14. J

    Grundfos Pump Plan valves sticking

    Yes roy, unfortunatley you do have to cut the pipe, the flap check valves are bulky and need 22mm iron to coppers, so could be a tight fit in a combi. The old flap type check valves are bullet proof, all of the so called heating type spring loaded ones I have looked at are to restrictive and...
  15. J

    Grundfos Pump Plan valves sticking

    If you mean the internal check valve, than YES prone to collecting crud. They come out easily with a large flat screwdriver, I then take a leaf from SMC'S book and cut in a seperate brass flap type.
  16. J

    Eurocal 90 Oilfired Combi Boiler - Fast Pressure Loss

    Water leak in the combustion chamber ?
  17. J

    Re-pressurise oil-fired combi

    You are looking for a flexible silver pipe, this will have a valve on at least one end that needs to be opened to let water into the system, fill-up to 1 bar pressure.
  18. J

    Descale Heatbank Worcester Heatslave Junior

    The coil can be descaled in-situ but specialist kit is needed, if your long on time and short on money drain down and swap over for your spare, and hope your neighbour had a scale reducer fitted :wink:
  19. J

    material for raised bed

    Hi, I plan on building two big raised beds for growing veg in, I have 12 scafold boards in good order. Is it ok to use them as edgeing or is it better to buy in something else ?, if I use them any recomendations as to what to treat them with considering their proximity to edible crops. thanks...
  20. J

    Cooker Boilers

    IMHO, and a long time working as a service engineer there is no such thing as a good range cooker that also serves as a boiler. They are a compromise appliance and do not perform either function well, they are inefficent and costly to maintain.