Search results

  1. G

    Can the boiler go above the hot water cylinder?

    That'll be fine - Just remember that someone will need to be able to get access to it and you will no longer be able to store stuff in the airing cupboard.
  2. G

    CH working but no hot water

    If you have an electrical backup I will presume you have a cylinder and do not have a combi boiler at all ??? Please clarify.
  3. G

    BAXI 105e combi - hot water/heating problem

    Unfortunately your description is not really suitable for diagnosis. Have you got hot water all the time? When you switch on the heating (With the taps closed) does the boiler do anything?
  4. G

    potterton suprima 50

    What revision PCB is in it? Does the green light goto "static on" or "flashing on"? Is there power on the switch live? Is there power to the pump? Is the pump running? Is there power to the fan? And does that run?
  5. G

    Lockshield Valve

    Some very old or cheaply installed systems don't have a locksield or return valve. Nothing to worry about; just prevents you from easily taking individual rads off the wall.... What is it you "actually" want to know?
  6. G

    Which Thermostat should i choose?

    I cannot recall or find any vrt378... I'm presuming this is just an obsolete stat. However; any zero-volt switching room stat will work... So my question has to be do you want wired or wireless?
  7. G

    sime combi hot water problem

    Keep number to yourself matey ;) As for the fault - First thing first... How far away is the tap from the draw-off? Has the problem only just occured or is it an ongoing issue? When you open the tap; if you look on the diverter valve; you'll see a sindle extend and hit a microswitch...
  8. G

    central heating and overflow pipes

    Couple of suggestions/statements: a) What pipe is "leaking"? b) Have you checked the tanks when the water is overflowing? c) Why have you changed all them components? Each one is easy enough to test - If you want support diagnosing it - Be more specific - System/boiler type; actual fault, etc
  9. G

    potterton boiler.

    How old is it? You may have the old PCB which will probably need replacing.
  10. G

    hot radiators when hot water only is on ,on a combi system

    Get a CORGI in; you'll probably need a new diverter valve depending on the combi model.
  11. G

    NEW BOILER

    How are they antiquated? 91% - A Rated efficiency 20 l/min @35 rise Upto 15m of vertical and 13m of horizontal fluing Class 5 NOX burner Range from 7-30kW
  12. G

    Ideal Response 120 - Hard to work on.

    I normally use a small adjustable spanner to undo them.... Otherwise a no.2 posie drive comes in handy :lol: As for the boilers - Keep an eye out for leaking heat exchangers and low water pressure switches.
  13. G

    biasi 24s would like to put external programer on

    Just wire 1 of the boiler 0v wires to the clock "common"; then the clock "on" to the room stat "common" and then the room stat "on" to the other 0v on the boiler.
  14. G

    biasi 24s would like to put external programer on

    Page 17 of the installer manual; shows a 0v switching line on the main terminal block for a room stat; something like a Drayton LP111 or LP711 will do the job... Don't forget to leave the old clock on constant :wink:
  15. G

    ferroli 1001

    Manual: http://www.gasaid.co.uk/manuals/Ferroli/FERROLI%20OPTIMA%201001%20GCNo.47-267-19.pdf Page 30 :wink:
  16. G

    draining twin-valve radiator

    Looks just big enough to get a tray under there; turn the valve off and the by-pass off; crack the nut; remove the rad and then connect hose to the rad valve. Alternatively; jump the microbore off and hook up to a hose; you'll need to get a bit imaginative with fittings; I now carry a BG hose...
  17. G

    Drayton SCR

    Change the batteries; think it's left then right hand draw if I remember rightly - Although without one in front of me; would not guarantee it. Don't forget to put the receiver into "learn mode".
  18. G

    Response gas pressure problem (UPDATED)

    I've never had this; so interested in this now; surely if it's a stabilsed inlet at 5.8mb it would be drawing off the meter causing the meter to then give a normal working pressure of 21.5mb??
  19. G

    NEW BOILER

    Megaflow with immersion would be my suggestion - At least then you have backup hot water when the boiler decides to take it's christmas vacation - We all know boxing day is one of the busiest :roll: If you are desperate for a combi; then I'd have to ask if this thing is going on a wall or...
  20. G

    Tempra 18 boiler. will fire up but will not stay alight

    Low water pressure switch is either blocked or faulty. Although I am not o-fay with this appliance so could not guarantee it.