Search results

  1. L

    Product Re-call. (many mcb's)

    This is what the wholesalers have been told if it helps ? How to Check Identify of the stock: Each product has printed upon its side date code. This code is a 6 letter code e.g. RSRSSR. However, only the last four letters need to be used in this check Simply compare the last four...
  2. Untitled

    Untitled

  3. L

    New Loft Floor advice

    Thanks for your reply The central wall is a brick wall that runs from the loft right down through the house to ground level so im assuming structural wall can you describe how to reinforce the 9x3 in more detail or can you think of any other way or am i basically snookered Thanks again
  4. L

    New Loft Floor advice

    I'm looking to beef up the loft floor for lots more storage only, nothing more. 1960's house the ceiling joists currently measure approx 70x40mm and span 3mtr from wallplate at back of house to middle supporting wall then another 3mt to front of house but these ones seem to be fixed to a...
  5. Untitled

    Untitled

  6. loft

    loft

  7. L

    WYLEX 10-Way Insulated High Integrity CU

    wf electrical are selling the flexible version wylex boards in their selectricals brochue the 10way board at £51.50 + vat 15way at £55.00 + vat mcb's 2.08 each + vat rcbo's 23.10 + vat so same equip would cost £107.32 inc vat (10way + 9 mcb + 1 rcbo) you can also buy exactly...
  8. L

    SET60CV Lighting Transformer

    coljack i said that most wholesalers will deal with aurora - not neccessarly stock their products on the shelf, but they as a company will have accounts with aurora and would be able to order it for you either directly themselves or via a stockist/distributor branch. The time of breezers...
  9. L

    SET60CV Lighting Transformer

    Breezer You posted at 10.46pm - That elec wholesalers in your area don't deal with Aurora, i'm pretty sure they don't at that time of night as i couldn't name one that opens that late at night most are closed by 6pm where i live. I can also understand most people would not know where to find...
  10. L

    SET60CV Lighting Transformer

    come on breezer - why the hard time you just need to google "aurora rd60" or "aurora au-rd60" and hey presto top of the page http://www.gwsupplies.co.uk/p/7291/aurora+35-60wva+round+transformer.htm# if they have none ring your local elec wholesaler i know for a fact that most if not...
  11. L

    SET60CV Lighting Transformer

    if you google rd60 you will find one in stock alternatively go to an electrical wholesalers like wf,neweys,cef etc they all deal with aurora
  12. L

    SET60CV Lighting Transformer

    not sure if you wanted that exact one but this one would maybe fit and do the job ?? aurora rd60 http://www.aurora.eu.com/ProductPages/PowerProductDetails.aspx?g=302&c=560&b=71&oc=560
  13. L

    Telephone wiring fault finding

    not 100% sure now as they live 30 miles away, i got them up and running via the master test socket and an extension lead for now but from what ive read and from what i remember it looked ok at that point. blue/white and whi/blue wires to 2 and 5 - not sure which way round orange/whi to 3 i...
  14. L

    Telephone wiring fault finding

    cheers breezer - sounds like a good start I was surprised to see 2 cables though connected to the master as i thought you only wired the slaves in series but this has 2 cables off the master going in opposite directions - so in effect 2 seperate slave circuits ? a telephone connected to...
  15. L

    Telephone wiring fault finding

    went upto to the inlaws to see if i could help them regarding their phone and internet problems as they were lost and bt were quoting £190 call out and high hourly rate if it was not bts fault. The phone quality was poor (faint and echo) i tried this on all the sockets inc the master and the...
  16. L

    peugeot 307 noise

    Hi, i have the above car and it makes a vibrating/dry rub type noise which increases and decreases with speed but if i press the clutch in it goes straight away, also it makes a clonking sound more often than not when turning left slowly but again only when driving not when coasting in neutral...
  17. L

    Tiling over underfloor heating mat

    Have got a sound concrete slab floor (Flat and level) 10m2 and am laying electric heating mat. One supplier has recommended 10mm insulation boards down then mat, them adhesive and tiles (They sell the boards by the way !! ) Another has said don't bother with the boards as my concrete slab has...
  18. L

    soil pipe and rainwater downpipe

    i know what your saying regarding the venting of the soil pipe i was gonna extended the soil pipe above the roofline and put a cowl on the top so its 900mm away from the window - but then im left with the problem of the gutter. Can i bring it down the wall and connect it into the soil pipe...
  19. L

    soil pipe and rainwater downpipe

    previously this rainwater down pipe was located here and went straight down into a drain located directly below, the old soil pipe was on the other side of the window shown and went straight down into a drain located directly below that, the 2 drains as far as i could tell were connected anyway...
  20. L

    soil pipe and rainwater downpipe

    its bloody cold at the mo so dont worry the window is firmly closed :lol: on a serious note can the rain water downpipe be connected into the soil pipe lower down ? and the soil pipe could be extended the required distance away from the window