  1. A

    Garden Driveway Lighting

    Hi, Currently in the process renovating the garden. I have a couple of areas where i am going to put in LED ground lighting which will be set in concrete driveways and a patio area. For this i have run 2 3cx1.5mm sq. armoured cables which will go to a waterproof junction box. Here these will...
  2. A

    What smoke detector

    I am fitting mains powered smoke detectors around the house. But the question is i have a utility room just off the kitchen, with a separate door. in the utility we have a washing machine and a tumble dryer, whats the best detector to fit here? should i fit an ionisation alarm here?
  3. A

    Hob isolation switch

    I am getting a kitchen island were there will be an electric hob situated. I am putting a DP (50A) isolation switch in a cupboard on the kitchen island, I ASSUME THIS IS OK?? can i just put the cabling form the hob straight to the isolation switch since there are in close proximity?
  4. A

    Isolation switch

    I am moving my CU to a new location and require the electricity board to re-route there cable but i was wondering has anyone fitted a isolation (trip) switch from there meter tails to the incoming 100A switch within the CU? essentially the switch would be next to the CU, i think its good for...
  5. A

    LV bathroom extractor fan

    i am installing low voltage bathroom fans with a humidisat http://www.alertelectrical.com/Fans-And-Ventilation/Airflow-Icon-Extractor-fans/Low-voltage-12V-DCSELV-extractor-fan---white-ICON30S.asp do these require a DP isolator, and can the FCU be mounted at a height near the ceiling...
  6. A

    immersion heater, ovens switches

    i have a 3kw immersion heater, so i am wiring it with 2.5mm sq.T & E to a 13A DP switch then from here some butyl (or something similar) 2.5mm sq. cable to the heater box is this ok? also i have wired 2 ovens from CU with 2.5mm sq. T & E seperately(rated at 3.5kw and 3.6kw) but since it...
  7. A

    Cooker question

    i have 2 ovens going into a kitchen single oven - 3.5kW combi oven - 3.6kw what cabling would be put in place for these, with them coming out at 15.2A and 15.65A does that mean they can be run on a T + E 2.5mm sq., just thought i have never seen 2.5mm sq. cable for cookers. would it...
  8. A

    electrical safe zones

    currently refurbishing my home, for existing sockets where can they be placed from the edge of a wall, i know the safe zone is 150mm from the edge so i presume you can move the socket as close as possible to this 150mm zone. its not a new build so i believe that i do not have to be 350mm from...
  9. A

    bathroom extract fan

    i am installing bathroom extract fans do these require to be isolated ie. from a Switch Fused Connection Unit? (does this require to be double pole or triple pole) can the SFCU be mounted at any height outside the bathroom? am i ok just to put the fan on its own ie. not on the light circuit...
  10. A

    light switch height

    hi all what is the height you are allowed to put in a light switch from the floor and also the distance from the door frame? i live in scotland
  11. A

    SOCKET POSITION

    Hi I am just rewiring my house I live in Scotland so i know that i am not affected by part M building regs. Is there anywhere that states the height of a socket and also how far from the wall is the socket allowed to be? I have read through the regs but nowhere does it state a height or...
  12. A

    Flooring, chipboard panels

    hi i am getting an extension build, 2 storeys, at the moment there is no ceiling on the ground floor so when i look up i can see that the some of the chipboard panels for the flooring above are not sitting directly on a joists/beam. i thought it would be best practice to have the joins...
  13. A

    Cooker Switch

    Hi I am putting in 2 ovens, combi microwave/grill and normal oven that will both sited next to each other. my question is can i run both of these off the same cooker unit switch or do i need a seperate cooker switch for each of them? also for a new build is there anywhere that states the...
  14. A

    MAINS INCOMER FROM ELECTRICAL SUPPLIER

    Is there anywhere thats states that the electricity company supply cable coming into the house, can this be run beside water pipes. Basically i am moving the meter and hence the supply incomer for the house into a cupboard which was going to house my consumer unit. Anyway i went back to the...
  15. A

    LOCATION OF A NEW CONSUMER UNIT

    I am doing extensive rewiring to my house and wanting to move the incoming meters and a consumer units. Is there anywhere in the 17th edition regs that tell me where i am allowed to site the new consumer unit? I am wanting to put it in an accessible cupboard but there is going to be a bathroom...
  16. A

    earth

    i have a friend who is installing a new light fitting into an alcove but its is a metal casing so has obviously has 3 wires from the fitting but the existing wiring within the alcove only has 2 wires. does this require an earth to be run from elsewhere?
  17. A

    ring circuit

    i am about to start re-wiring my house due to an extension being build. I was an electrician a few years ago so unsure about all the reg changes. For a ring circuit i know that it has to be within 100m sq. but is there a maximum length of cable? i have concrete floors in new extension so have...