Glow Worm Hideaway 90 tripping RCD

  • Thread starter Thread starter OJ
  • Start date Start date
My usual meter will read up to 2 Meg as a low voltage test. It also reads current from 1 mA as a clamp on for dealing with earth leakage problems.

Thats usually adequate for my daily fault finding but if I needed additional testing then I have a 500v test Megger for insulation and voltage breakdown tests.

Tony
 
Until such times as I get someone to look at this - I presume it is ok to use the Immersion in order to get hot water.....?
 
I wonder how common it is for engineers to have that equipment :lol:

Anyone who cannot measure earth leakage will be unable to diagnose faults causing RCD trips except by parts changing on spec.

Measuring insulation at low voltage to 2 Meg is also required to identify wet detection electrodes and many insulation faults.

The single meter I use for that costs under £30.

Tony
 
Until such times as I get someone to look at this - I presume it is ok to use the Immersion in order to get hot water.....?
 