I forgot to ask ....
What it 'contravenes' is the deemed-to-satisfy suggestions given in Appendix 15 of the regs - which, incidentally also do not mention having two FCUs on one spur (even though that's no different from a double socket). As often discussed, that doesn't mean that one cannot comply with the regs in ways not mentioned in that 'informative' Appendix.3 FCUs on one unfused spur contravenes the regulations....
so, the question .... What would you say if the 3 FCUs were supplied with a 4mm² spur from the ring?
Kind Regards, John.
YES IT IS!!!
Because 2 spurs is 2x 13A accessories and a double socket is 1x 13A accessory.
The days of two accessories allowed on an unfused spur went out with the 14th.
I shall stand with head held high as I get shot down...