Recent content by Alex evans

  1. A

    Replace landing light fixture. Wiring.

    Looking to replace light fitting at voth bottom of stairs and top of stairs. Both lights are operated by both... The bottom or/and top of stairs. This is the existing. How should i wire the new light, which has N / E /L ---- how i read it is... - the existing neutral to N - the existing...
  2. A

    Toilet flush not working. Siphon or drop valve?

    Wasnt aware you could just replace the membrane. To be fair, as its out. I might as well change that whole part, right? And for a few quid, new do'nut kit..... belt n braces
  3. A

    Toilet flush not working. Siphon or drop valve?

    Hi, my toilet wont flush very well. The handel is loose and you have to sort of pump the handle quickly to have a chance of a flush. Anyway. I cant see online is its best to replace the syphon like for like. Replace for a (more modern?) drop valve ? Such as attached? Should i Replace the...
  4. A

    Opinion wanted: what would YOU do with this space?

    Hi all, thanks for clicking. So .... In short: we want a "bigger" parking area...abit of space to walk around the car, getting kids in and out ect. Were on a bit of a budget and totally diy. Budget: up to £900-£1000 My thoughts were to fence off and dig out the grass, the "patio bit" and dig...
  5. A

    NEW Viceroy extractor not working

    Hi guys. Just wondering if anyone here has had a similar situation or know if theres something im doing wrong. Fitting a new kitchen, weve installed the hob extractor. Plugged it in, you get a beep. But the touch buttons dont do anything. Im obviously trying to contact the people who make it...
  6. A

    Can you put 2 cables on load side of a single fcu?

    Right! That makes sense, yeah. Would i be able then, to fit an fcu in the cable that goes from the existing socket to the existing fcu. Edit:. Or. Probably easyer, to just cut into the ring main cables, fit a new fcu.
  7. A

    Can you put 2 cables on load side of a single fcu?

    A spur, off of the ring main. Edit: ie see drawing
  8. A

    Can you put 2 cables on load side of a single fcu?

    Hi guys. Got a fcu off of the ring main to then supply power to a gas boiler. Simple enough. Im looking for a way to get an outdoor socket fitted in this area, and am wondering if i can put a cable from load side (so, along with the boiler flex) to the new outdoor socket. I cant see a problem...
  9. A

    Planning a kitchen. Question about 2 ovens

    Hi guys. Im trying to plan a kitchen layout ect. Ive a question (which im pretty sure i know the answer to) regarding ovens. Currently... Its pretty standard. 6mm cable straight from the fuseboard, (32amp??) Goes to a cooker connection unit. From there it goes to a freestanding cooker AND hob...
  10. A

    2 appliances, 1 waste pipe. What fixture do i need?

    Only if it had the voice of John Cleese!!!
  11. A

    2 appliances, 1 waste pipe. What fixture do i need?

    Hi guys. An easy (hopefully) one for you today. Please see attached current set up in the UTILITY ROOM (GARAGE! ) At the moment its a WASHING MACHINE WASTE going into the 40(?) mm waste. Happy days. Were looking to put a CONDESCENDING dryer next to this appliance. (The type that condenses...
  12. A

    Can somebody link me a fitting for this purpose? Screwfix or amazon preferably

    Hi guys. Ok so my cold bath tap has stopped working. Probbaly cartridge, no worries ive got a replacement tap. However... I cant get the old tap off as it's THAT old it seems rusted/fused on. So my plan is to cut that fitting off and replace. So the thread on the tap itsself is the same as the...