Recent content by D1nhs

  1. D

    Painting an old cupboard black

    Hi Guys I have a fluval roma fish tank which sits upon its own wooden stand like this... http://www.aquariumsdelivered.co.uk/catalog/images/Roma240_bch_large.jpg I want to paint it matte/satin black, can you all advise the best way to do this with the best finish? I was thinking of...
  2. D

    Trapped water behind tiles?

    Used Bal powerderd grout, said it was suitable for swimming pools! Yes fixed with notched trowel for flat bed of adhesive. All othe tiles are fine, just the bottom row. I like the sound of your technique regarding the gap. I siliconed using dow corning around the shower tray between the...
  3. D

    Trapped water behind tiles?

    Hi guys! Setup: Corner shower enclosure, aqua panel, tanked, and tiled, siliconed along edge of shower tray and up vertical corner. Observation: Mould has developed over approx 12 months in the silicone, bottom row of tiles are a darker shade almost as if they are damp from behind. I...
  4. D

    Does size matter? :)

    Cheers RF :)
  5. D

    Does size matter? :)

    So following suggestions on this site i went for a larger 7.2 battery for my Texecom Excel system. Now when fitting, its quite a tight squeeze and had to push some cables out the way. A friend said that the panels can get quite hot and i should get a smaller one to make more room...
  6. D

    Texecom Dialler - No Dial tone

    Just a follow up, fitted a new dialler and it was the same. It turned out to be a dodgy telephone extension cable, i bought a really thin and flat one. Turned out to be cra p. So replaced with a colid, BT approved one and it worked firt time! Thanks again for your suggestions
  7. D

    New Texecom control panel buzz

    Cool will try that thanks mate!
  8. D

    New Texecom control panel buzz

    Just installed a Texecom excel contol panel. Ive noticed that there is a very small buzz coming from the control panel. This normal? Could this be that ive wired something up wrong? Thanks
  9. D

    Texecom Dialler - No Dial tone

    Tried that too still didnt work. I spoke with the alarm shop and they are happy to exchange it. So lets see Thanks again guys
  10. D

    Texecom Dialler - No Dial tone

    Thanks for the suggestion, yes ive tried that also. I called texecom helpdesk today, and was told it could be 1)noise on the line eg ADSL which i dont have. or 2) a dodgy dialler So im going to try and send it back and get a replacement Wish me luck!
  11. D

    Texecom Dialler - No Dial tone

    Ive used the supplied plug in lead conenction. I dont have adsl, but tried a filter anyway, and it didnt work thanks for the suggestion :) Ive triple checked the settings and its set to the standard config, where it waits for a dial tone first. It doesnt get to the dial stage, just waits...
  12. D

    Texecom Dialler - No Dial tone

    Hi guys, Just fitted a texecom excel system. The dialler is all connected as described in the manual with all programmed numbers etc. When testing the dialler attempts to dial the first number, although after about 10 secs it times out and reads 'No dial tone' Ive checked the line...
  13. D

    PIR facing sliding door or radiator?

    Thanks Denford, i bought Texecom QDs they are quads. Im going to take a gamble and mount facing the radiator wish me luck!
  14. D

    PIR facing sliding door or radiator?

    Im siting a PIR in my dining room. On one side of the room there is a sliding patio door, on the other side there is the radiator. So which side shall i site the PIR? Ive read it shouldnt face a window or radiator?? Thanks
  15. D

    Boiler Hot Water Sensitivity

    My Bad! Tis a Worcester 35 CDi II Thanks
Back