    domestic 3 ph supply

    has anybody had a 3 ph supply installed into there property and roughly how much it costs . my house is running 60A when heating on and voltage drops to 220v its at 15A and 240v when heating off . is 60 A excessive in modern times ???
  2. R

    lpg gas supply pipe size

    my mates lpg gas boiler packed in and he has bought a 40 kw combi system and he has a large lpg cooker . the old system was running on 3/4 thick wall galv pipe from tank and 15 mm copper inside . the new boiler connection is 22mm what size pipes should he be using???
  3. R

    lights dim when ch boiler starts up

    yes it is , its an old property on a farm
  4. R

    lights dim when ch boiler starts up

    getting scottish power out to do a load test ,might need a 3 phase meter
  5. R

    lights dim when ch boiler starts up

    yes qualified heating engineers fitted system , main fuse was 60A he upgraded to 80A lights used to dip slightly before but worse with the higher load
  6. R

    lights dim when ch boiler starts up

    just had a 12 kw aztec electric boiler fitted today and when it kicks in the lights dim and when it cuts out lights get brighter again . do i need a bigger incoming supply/meter/fuseboard ??????
  7. R

    morso stoves any good???

    thanks for the replies do any of your stove's have problems with coal & logs rolling against the glass its a big problem with my hunter
  8. R

    morso stoves any good???

    ive got a hunter herald 14 at the moment with a ch boiler in it , totally useless for heating a house and its got a few design faults
  9. R

    morso stoves any good???

    im looking for a new stove , does anyone have a morso squirrel ?? are they any good
  10. R

    hunter herald 14 plumbing

    im having a few problems with my ch and im wanting to check plumber plumbed in in correctly , does anyone have a hunter stove with a wraparound boiler.
  11. R

    radiator's barely warm

    2 x 500 singles 5 x 1200 singles 1 x 800 double 1 x 1200 double
  12. R

    radiator's barely warm

    ive got a multifuel stove which has a water output of 13 kw ive got 9 radiators in the circuit and a hot water tank . after fire is lit and up to temperature the pipe that goes to the hot water tank gets hot and when the return to fire gets hot the radiator pump kicks in and within an hour all...
  13. R

    High Pressure?

    i also have a pressure reducing valve and i have it set at 4 bar and have no problems
  14. R

    velux window air gap

    im building an extension and am planning to install velux windows into the roof but im concerned about the air gap after i install the window , how will the air flow over this section of roof if the window is installed ?? any ideas anybody
  15. R

    old size copper pipe

    im installing some new pipework in my bathroom can you get adapters from the old sixes to the new sizes my pipes are slightly smaller than 22mm and slightly smaller than 15mm
  16. R

    plaster board

    im planning to replasterboard my bathroom behind bath annd shower cubicle as previous owner did not beleive in grout and wall was all black , and im wanting to put insulation into the cavity do help with noise . do i need special plaster board for bathrooms???
  17. R

    mains water pressure

    ive a problem with high mains water pressure and have ordered a pressure reducing valve , but what pressure should i set it at ???
  18. R

    laying laminate

    ive layed a few laminate floors before but my new living room has two large radiators on different walls. ive always started at the radiator previously to make life easier for myself but with two radiators , where do i start?????