  1. S

    Is this safe??

    cant see any probs with that set up :D
  2. S

    Outside Light

    yes you would have to feed a new cable to the proposed outside light a light requires live and neutral to work,however the switch only has lives passing through it. as you can hopefully see you would need to supply the new light with a neutral so that when the switch is toggled the lamp will...
  3. S

    No Light!

    have you got a little "jumper cable" linking both commons together? if the light works when you connect it to s1 it tells me you do not have "live" on s2 :?
  4. S

    Replacing old Fuse Box with modern consumer unit

    sorry just seen this, IT IS NOT LEGAL to pull the fuse I was merely stating that by doing so would "kill" power to the meter as the poster asked. and yes i do have a supply of seals :lol:
  5. S

    Not outrageous prices

    can you post a link SS i feel a purchase coming on :lol: :lol:
  6. S

    2 gang switch help.

    red from each cable to com black from same cable to L1 :lol:
  7. S

    Replacing old Fuse Box with modern consumer unit

    unfortunately for you part P is now inforce and this job IS notifiable to your local council and as such you'll need a certified electrician(under 1 of the part p scams...sorry schemes to do the work for you) or else involve the local council (££'s) to answer your question yes you can...
  8. S

    Which cooker hood

    which model is entirely down to you most modern ones come with carbon and foam filters so can be used without ducting through walls however the ducting method is definately better. how are you going to get power to it? :?
  9. S

    Consumer Unit Terminology

    the 5x5 relates to.... 5 x mcb NON RCD protected, 5xMcb RCD protected hope that helped! :D
  10. S

    replacing a Randall 3022 with new electronic timer

    ive sussed it now i had'nt looked at the MK3 series on randall website only the 3022 link many thanks to all who helped steer me to the answers i needed :lol:
  11. S

    replacing a Randall 3022 with new electronic timer

    if it were just that chris i could sort it easy but i dont understand the plumbing terms described in the 3022 wiring guide at all to be able to know what is ch on/off etc
  12. S

    replacing a Randall 3022 with new electronic timer

    i have to deduce live/neutral (easy).... heating on/ heating off... hot water on/hot water off (far from easy) hence using all 6 terminals of new controller :oops: :cry: :cry:
  13. S

    replacing a Randall 3022 with new electronic timer

    the new controller has live/ neutral and 4 other connection terminals (total of 6) wheras w plan calls for live /neutral and 5 other (total 7) bugger :evil:
  14. S

    replacing a Randall 3022 with new electronic timer

    ive forgotten to mention the new controller is a randall danfoss FP715 i was hoping that with it being from the same manufacturer i could just unplug and replug new one ( :oops: :oops: ) clearly not that easy!! :cry:
  15. S

    replacing a Randall 3022 with new electronic timer

    any chance of a link to the w-plan schedule? ive been to honeywell site and cant seem to find it many thanks for help so far spence
  16. S

    replacing a Randall 3022 with new electronic timer

    im at the property tomorrow but owner confirmed that it is a honeywell but no model type i take it the motorised valve type is critical then and i cant just wire it generically? :oops:
  17. S

    replacing a Randall 3022 with new electronic timer

    tks for replies i had found that link to the randall danfoss site but must admit to having a few problems translating the wiring to equate to heating on/off and HW on/off any advice .......please :?
  18. S

    replacing a Randall 3022 with new electronic timer

    does anyone have any idea of wiring arrangements for a Randall 3022 controller? the new controller requires on DHW / off DHW on HTG /off HTG any ideas gents??
  19. S

    How many phone extension sockets can you have from a master?

    its also possible to purchase a REN expander small box that connects in the circuit and i believe allows you to expand the REN as high as 16 i.e if the ren of your phone is 1 you can have upto 16!!
  20. S

    Part P? Question.

    as im predominately a "house basher" for what its worth i very often work sundays but its rare i work a proper 'night shift' only time i work at night is if im called out to a problem obviously not one of my own jobs....you understand :D