Search results

  1. H

    Oven flex size

    thanks, the circuit is protected by a 32A MCB. Also on this circuit will be a hob and the socket outlet.
  2. H

    Oven flex size

    Hi Can anyone help me determine the size of the flex cable I need to install on a Siemens oven? It's rated at 4.9kW and the manual states it needs to be wired using a type H05 VV-F or higher. Thanks Howie
  3. H

    Connection Current setting on Siemens hob

    it points to setting it at 20A, has anyone come across this issue before on Siemens/Bosch/Neff hobs?
  4. H

    Connection Current setting on Siemens hob

    Tried that already and spoke to 3 people who either didn't understand or couldn't help. I even tried to speak to Siemens direct with no luck - so here I am. I've taken a look at the listing you refer to and it doesn't indicate which current to choose, hence my post. I'd be grateful if one of...
  5. H

    Connection Current setting on Siemens hob

    Hi, can anyone help with some advice on an induction hob: According to the manual, before you use the hob for the first time you need to select the connection current and walks you through a step-by-step instruction of how to select the current you need. My issue is knowing the correct...
  6. H

    Garage roof condensation

    I have a huge amount of condensation forming on the underside of my garage roof. The roof is constructed from corrugated steel sheets and would like some advice on how to tackle the problem. I am thinking of insulating the roof by putting up a false ceiling and insering rockwool in the void...
  7. H

    Supplying power to a two gang switch

    excellent, thanks dude.
  8. H

    Supplying power to a two gang switch

    Im going to install a two gang light switch that will supply two seperate lights, can I simply loop the live feed from L1 in the swtich to the other L1 terminal to provide power to both lights, instead of running two power cables from the consumer unit? Thanks for your help Howie
  9. H

    lighting circuit for outdoor building

    hello all I want to add a lighting circuit to my garage but I am confused as to what to use in replace of a junction box as used in a conventional indoor lighting circuit. Most of the examples I have seen don't use a junction box. Do I just run the power cable to the swith and then back to...
  10. H

    cement pigments

    Does anyone know if you can get black cement pigment and if so where you can get it? Cheers
  11. H

    raised decking over tarmac

    I building a decking area over tarmac, does anyone have any ideas on how to secure the vertical posts to the tarmac? I can't use fence post supports as they would be too big, the raised portion of the deck will only be 5" off the tarmac. Cheers
  12. H

    rendering a retaining wall

    the problem is that the wall has been built with an assortment of block and brick and really could do with rendering, is there a lime based render I could use instead of sand+cement? Thanks
  13. H

    Drilling into Patio Stone

    I find if you're not using an SDS drill then try using progressively bigger bits - start at say a 4mm pilot hole and work up to 10 mm in 2mm stages.
  14. H

    rendering a retaining wall

    I've been thinking about rendering an outside 3m high retaining wall and am concerned that I will be interfering with the walls ability to get rid of moisture from behind it. Has anyone got any experience of this problem?
  15. H

    rendering

    scuze my ignorance but what does rubbed up mean? Cheers JB
  16. H

    rendering

    thanks for the info, when do you use the sponge, ie after a couple of hours drying time and does the sponge need to be wet? Cheers
  17. H

    painting chipboard

    hi there does anyone know if it's possible to paint chipboard, ie. will it swell on application of the paint? cheers Howie
  18. H

    rendering

    Hi there I'm about to embark on rendering an outside wall and was hoping for some pointers. I'm trying to achieve a smooth finish using a plastering sand and cement mix, is this achievable in one coat and how do get a good smooth finish? Any help would be greatly appreciated. Cheers
  19. H

    Earth detection

    Thnaks for all the replies guys.... Sorry for the ignorance, but what is and where can I get the OSG? That's another problem - there is no bonding, except under the new boiler where all pipes beneath have been cross bonded. My plan is to bond the gas and mains water back to the CU and...
  20. H

    Earth detection

    I think you're right, not being able to see an earth rod and it's connection is not very reassuring. Is installing a new earth to rod circuit within the capabilities of a competent diy'er (i.e. are there any tests required post installation)? If so would you use 16mm or 10mm earth cable to...