Search results

  1. tininho

    Boiler runs hot and cold

    DHW sensor or Div/Valve cartridge fault most likely. Have you noticed if your radiators begin to heat while the tap is running?
  2. tininho

    Can anyone tell me what pipe diameter use from Meter-Boiler

    I assume you're not carrying this work out yourself? A RGI will be able to do the pipe sizing for you.
  3. tininho

    Short circuit test

    well, yes it does Short circuit is the correct term. Continuity just means that its not open circuit - that there is a conductive path. It's a term used by those who do not have the correct equipment or who don't understand how to use it Well, no it doesn't A short circuit relates...
  4. tininho

    Boiler pressure

    Either, water leak, pressure relief valve passing or expansion vsl needs re-charged or replaced. Martin
  5. tininho

    connecting a combi

    The quck answer would be yes. Your combination boiler heats up the water as you use it and therefore doesn't require a store of hot water.... Much more efficient..... However, I would never pay, or charge some-one £1000 to connect it. All that needs done is, cold mains to domestic inlet of...
  6. tininho

    ferroli modena 80e hot water fluctuating on and off

    Either that or the fan venturi Martin
  7. tininho

    Ideal isar HE30 noise problems

    Hi, The isar has a built in hot water preheat which will cause the boiler to fire periodically whether you have created a heating demand or not. do the rads heat when it fires at these odd times? Martin
  8. tininho

    water heaters

    There really isn't a correct answer here...... it depends on the immersion you are using if it's a direct cylinder, and depends on the heat input of the applance you're using if it's indirect (I assume we're taking gas???)....... It's probably cheaper to do it indirectly with gas too...
  9. tininho

    Combi boiler burner keeps coming on and off

    Hi a thermistor works based on resistance. the higher the temp of the water the greater the resistance across the thermistor, thus modulating the burner down to maintain a constant temp. In essence the thermistor resistance could be higher than it should be, in effect telling the boiler...
  10. tininho

    Combi boiler burner keeps coming on and off

    Hi, Don't know the boiler particuarly well, but sounds like a DHW thermistor fault to me. Hopefully, someone else here knows the appliance better than i do. Martin
  11. tininho

    fault on pump BAXI COMBI 105HE

    When you were carrying out the work (after re-filling the system), did you open the boiler??? Sounds ilke the pump may have been air locked. What is the current system pressure?? Martin
  12. tininho

    British Gas - New System - Are they really the devil?!

    1CANHELP, No dis-respect, but I find your comments on BG/SG engineers rather unfair. I have come across quite a few engineers who completed a 3 or 4 year app, and quite frankly wouldn't have trusted them to wire a plug.... In return I know engineers who completed the year and a half course...
  13. tininho

    British Gas - New System - Are they really the devil?!

    Hi, To be honest, a lot of the "bad press" comes from ex employees, who's opinions are based on their own bad experiences of working for them..... As an employer they have faults ( as does any company) However, you can be sure that if BG do your install, you're warranty will be honered, and...
  14. tininho

    fault on pump BAXI COMBI 105HE

    Sorry, should have asked, what is the current system pressure???? When you say you opened the bleed valve, do you mean on the towel rail, or the pump inside the boiler??? Martin
  15. tininho

    fault on pump BAXI COMBI 105HE

    Hi, Could be a couple of things.... Firstly, after opening the auto air vent, did you leave it open, or close it again??? Secondly, does the pump sound as though it's running??? If you closed the auto air vent, the pump could be air locked.... If not, the pump could be stuck..... If...
  16. tininho

    broke motorised valve lever

    Hi, I wouldn't recomend it, but the motorised valve could potentially be jammed open with a screw, or something of that sort.... As I say, I wouldn't recomend it.... Just take the hit and get a new motorised valve. :roll: Martin
  17. tininho

    Yellow gas service pipe only 100mm deep

    I seem to remember reading about this. The depth of the pipe in a garden or private footpath is ok at 375mm, or 14.7", where-as a public footpath or road would need to be deeper because of the additional pressure on the surface.... I think Transco will stick to the old, "it's on your...
  18. tininho

    Boiler unsafe due to flue

    Hi, (Any info given regarding safety of flue, or gas safety can't be guaranteed to be completely correct, as I haven't seen the job) The safety of the flue termination within a carport is dependant on more than one factor.... I would need to check the regs to be sure, but I believe...
  19. tininho

    Baxi bermuda back boiler

    You're really limited to the fire front you can have with BBU's.... As fire and BBU are considered 1 appliance not just any fire can be fitted.... You might be able to track down a like for like I suppose.... Martin