central heating

  1. E

    Baxi 60/100 and Hive

    Have searched the site for solution and couldn't find one for my problem, hopefully someone is able to advise on where I have went wrong. Formerly had potterton EP2002 controller connected to my BAXI system boiler 60/100. (See photo) This also had a thermostat wired in and has a hot water...
  2. B

    Heating design - underground pipes with external boiler

    Looking at where to place an external boiler, and some guidance on best practice is needed! Very conventional system - heat-only oil boiler, fully pumped, Y plan, indirect cylinder, F&E tank, 7 rads, all in a 2 bed cottage. It's a spring-supplied system, not on mains, so there is only 0.5 bar...
  3. S

    How much space from flue to shed

    Hi, I’m looking to relocate a shed. Does anyone know what the UK restrictions are as to how close it can be placed to the external flue? It’s one of the types of flues which emits straight out, its a new build. I presume there is a radial distance? thanks.
  4. Gwreay

    Drayton ZA5 zone valve actuator not working

    Afternoon, First post on here but you all seem like a really helpful bunch, hoping to find the problem with my valve. When called for heating there is no movement in the motor, we put in a new one just incase and still nothing. I've measured the voltage across the points powering the motor...
  5. Oceans247

    Best heating and hot water system for a full reno terraced 3 bed house?

    Hi there, I am doing a full renovation on a mid-terrace 3-bed house (inc loft) and single-story rear extension. It will have 1 family bathroom with bath, and 1 ensuite and 9 to 12 rads (inc heated towel rails. Electric underfloor heating in family bathroom and ensuite. I was going to put in a...
  6. R

    Boiler fires up for H/W but not C/H

    Hello all, I’m pretty clueless when it comes to this sort of thing but as we can’t have tradesmen in the house due to shielding I’m hoping someone can give me advice to help diagnose my heating problems. We bought this house less than a year ago and starting to find that there are several...
  7. P

    Pex pipe-boiler: aerial distance

    I am adding radiators to my 2-pipe pumped, vented central heating (UK). The whole piping is copper 22mm and microbore, and I'm extending it with 15mm pex barrier pipe graded for central heating. I know that the first bit of pipes connected to the boiler must be copper, which is the case...
  8. D

    Outdoor housing for Grant Euroflame 70/90

    Hi, hope everyone's keeping well. I would appreciate some advice. Our house came with an old FireBird boiler which is well and truly dead. My Dad recently converted to gas (not available in my area) so has a Grant Euroflame 70/90 Boiler sitting unused in his garage. It's only 2-3 years old and...
  9. W

    Honeywell programmer program

    Hi all, Sorry the title should have said problem not program! My Honeywell ST6400C central heating and hot water programmer has just gone wrong. I took it off the base plate and cleaned out the dust then put it back and pressed reset.Now I can set the date and time and programme in the heating...
  10. Markbrand7

    Vokera compact 28 he issue

    Hello, I woke up this morning with the boiler flashing every 0.5 secs after realising the water wasn’t heating up. I have tried leaving the filling loop open and only fills to 3.5 bars. I have bled all my rads and it is now at 1.5 bars but I still have the same issue. No heating or hot water...
  11. W

    WD40 terror and zone valve

    Hi all, Drayton ZA5 valve seized the other day during this Corona lock down. Took off the actuator head and sprayed the tap itself with silicon lubricant, but no luck, still too hard to move with pliers. Only thing that freed it was WD40. I am now terrified the WD40 is gonna eat the seals...
  12. D

    Ariston Class One low temp

    Hello, I have Ariston Class One (condensation combi boiler) and the problem is that I cannot get the desired temp. at my house. I have floor heating in the living room and 2 radiators in the bedroom. It cannot get 23C or sometimes it reaches the 23C but very slow. This is a new installation...
  13. D

    Baxi Megaflo 28 System ErP General Query/Help

    Hi! So I have just moved into a new house and it has the above boiler fitted and I am trying to understand it as best as possible. The control is set to water and central heating, Normally there is a temperature control for the central heating and then one for the water, but this is combined...
  14. 3

    Central heating misery (or mystery)!!

    Hi hope somebody can help! We've had our open system boiler upgraded to a Viessmann Vitodens 050 combi back in August last year. When we had the heating on the first time in November when the thermostat was set to 20℃. After giving birth and having parents coming from the far east to help out...
  15. I

    Partial system draining

    Hi, I'm just starting on a major renovation, beginning with the bathroom. I've been reading this forum for a couple of months and have discovered a wealth of useful information and answers to nearly all my questions without having to ask them! I do however have a couple of questions to start...
  16. B

    Thermostat - best replacement

    Hello and thank you for reading this message. One of two thermostats broken. Honeywell. One controls downstairs and the other controls upstairs. Installed approximately 2006 in new build house. Gas central heating. New boiler installed 2018, believe Vaillant ecotec fit 24. Photo attached...
  17. P

    Satchwell LT25 to Flomasta2923G

    Hi, can anyone please help? My old Satchwell LT25 room thermostat has 6 terminals 1-5 plus an Earth, but only has 3 wires, Brown to 3 Blue to 1 Yellow to Earth.. The Flomasta 2923G wired digital non programmable thermostat has: NO - Call. NC - Satisfied. COM /LIVE. What goes where please...
  18. M

    Central heating system - hot water won’t switch off until whole system shuts down

    Hi I’ve got many fingers crossed in the hope that some of you good people can help me... It’s an ‘S’ system traditional gas boiler with a hot water tank and radiators, with two 2-port valves to separate the HW and CH parts of the system. I can use the programmer no problem to fire up either or...
  19. S

    Will a BG WPT1 work with Hive Hub?

    Hi I've got a combi boiler with a British Gas WPT1 wireless thermostat and hive single channel receiver. I'm thinking about upgrading to a full hive system to be able to use the mobile app etc, so could anyone tell me, can I just buy the hive hub and continue using the BG WPT1 thermostat and...
  20. H

    Problem with Digistat RF2 Central Heating Thermostat

    This has been in the house from before I moved in 11 years ago. I've had some issues with it over the years, but generally it works ok. My current problem is that it is supposed to raise the temperature from what is displayed by pressing the Plus button. For the time period programmed in it...
Back