vaillant

  1. M

    Shortening a Flex Stainless Steel Pipe for ASHP?

    Hi Everyone, I was wondering if anyone knows of a way to shorten a flexible stainless steel flex hose for a Vaillant ASHP? I have previously purchased flex connection hoses from Vaillant that could be shortened using a circlip, but it would appear that they have changed their manufacturing...
  2. D

    Weather sensor for the 2023 Vaillant Ecotec Plus 832

    I have the 2023 release Vaillant Ecotec Plus 832 installed (touch screen display at front). It was installed with a Wolseley Centre wireless controller however the radiators were taking 50 minutes to 1 hour to come up to the target flow rate of 60 degrees and after much misdirection by Vaillant...
  3. E

    Strange boiler pressure loss scenario

    Hi there. We have a Vaillant system boiler which has recently had a new expansion vessel and PRV. However, we still have some kind of pressure issue. The pressure remains pretty constant with daily checks and similar usage patterns (typically 1.4 or 1.5 bar) for about 4 weeks, but then suddenly...
  4. M

    Vaillant AeroTherm U.K. vs EU version?

    Hi Everyone, Does anyone know if there is a difference between the Vaillant AroTherm Plus 7k sold in the U.K. vs the EU model? I can see that there’s a huge price difference with items such as the VRC 720 F wireless controller and that generally speaking the AroTherm Plus is sold separately to...
  5. M

    Vaillant Arotherm 7KW Heat Pump Controllers???

    Hi All, I am considering installing a Vaillant Arotherm Plus 7kw heatpump in my house. Does anyone know if the Arotherm Plus 7Kw includes a controller unit (wiring center)? I previously lived in Denmark and Vaillant supplied a seperate VWZ AI Controller and this could be paired with a Vaillant...
  6. W

    Vaillant ecoTec Plus 630 boiler not reaching target temp

    I recently had a new 2023 Vaillant ecoTec plus 630 (30kW) system boiler installed along with a Low Loss Header (LLH) in my house. I have 21 rads in the house and a room with UFH. The LLH was introduced as I was finding (before the LLH was fitted) that my old boiler (Vaillant heat-only boiler)...
  7. Auric

    Water dripping out of flue and into boiler - an easy fix for DIYer?

    Hi all I noticed water dripping from the bottom of my Vaillant combi boiler and found the source to be the base of the flue where it connects to the boiler (as in the photo below). I've sent pictures to the boiler installer but he's ghosting me. Is this something I can fix? Tighten up the...
  8. C

    This site does not support DIY gas work (Ed.)

    .
  9. eveares

    Do any Vaillant weather compensating controls support traditional hard wired thermostats?

    I have have a Vailant EcoTec Plus 937 boiler that is about 10 years old. During it's first few years, I had the VRC700f control with the wireless outdoor temperature sensor, that modulates the flow temperature based on the outside temperature. Unfortunately the outside weather temperature...
  10. G

    'Tinkling radiator' - New Central Heating Conundrum (Full-on Vaillant install)

    I’ve just had a full central heating setup installed into my ‘older’ property. Mostly, everything feels fine (and warm). The one adverse symptom is that one (high capacity) radiator in the living room occasionally but regularly ‘tinkles’. I’ve repeatedly bled the system but this doesn’t alter...
  11. W

    Vaillant EcoTec Plus 826 - is it too small and what controls to use?

    Evening all, I'm looking to have my 50 year old conventional boiler replaced with a combi, and may have a HWC added in a new location at a much later date. The current boiler is a Potterton Netaheat Electric 16/22. The teeth on the knob on the front have gone so the actual setting is somewhere...
  12. H

    Valliant boiler grinding noise

    So a couple of weeks ago we noticed the boiler making this noise (see vid), its much louder than we've known it to be, and there seems to be condensation or steam coming out of the hole in the top. Strange thing is that it only makes this noise if we run the bath, the sink taps or heating do...
  13. M

    vaillant thermostat wiring

    Hi All Vaillant ecotech system installation (+ tank for Domestic Hot Water), single zone. Current thermostat is a wireless salus, with a drayton programmer. Myvaillant connect will be installed to program heating times via phone app, directly on ebus connection so no wiring headache for this...
  14. T

    Vaillant ecofit boiler noise

    Hi, I had a Vaillant ecofit pure 830 combi installed at the beginning of the year. Flushed and new protection kit fitted, etc. Came back from a 2 week holiday and now I'm getting a horrible loud pulsing noise that vibrates through the house. Happens with both ch and hw. Have attached a short vid...
  15. W

    Hive wiring Vaillant boiler

    I’ve just wired up a hive thermostat to my Vaillant ecotec plus 824 boiler. The hub, thermostat and receiver are all paired. The receiver clicks on when turning thermostat up or using via app on iPhone but the heating itself isn’t turning on. It’s like it’s not getting the signal from the...
  16. S

    Vaillant Ecotec Plus 637 Pump over run problem- Please Help !!!!

    Hello Folks and Especially those that are averse to Vaillant prooblems I have an Ecotec plus 637 systems boiler not sure if its S or Y plan but will poost pictures. Theres a wireless room stat in same room and a Valliant control center too. All has been running fine for absolutely ages until...
  17. eveares

    Vaillant Ecotec 937 plus - Flu fan constantly on, LCD dead, No heating or hot water - Common fault or not?

    Had a short power cut earlier and when the power came back on, it looks like my Vaillant Ecotec 937 plus boiler died. My educated guess is either when the power went out or when the power came back on, the PCB on my boiler died, as now it is completely unresponsive (LCD dead, no heating or hot...
  18. M

    vaillant System boiler in s plan, sensocomfort vrc720f with ambisense TRV

    Hello Everyone, Has anyone had any experience with vaillant System boiler in s plan, sensocomfort vrc720f with ambisense TRVs as i was using an old WB combi boiler with Tado at my house but my builder said he wont be able to make tado work with the viesmann 100 in s plan so I am really looking...
  19. S

    Vaillant echo tech plus 418 short cycling on hot water but OK for central heating. Best recommended settings

    Hi I have moved to a different home which has Vaillant Echo tech plus 418 boiler installed with open vented cylinder and a central heating system. The thermostat on the cylinder is set to 60C and the boiler has two radial dials in front to control the flow temperature, both of which are set to...
  20. D

    Replaced Vaillant VR21 with VRC DCF (9535) not working

    Hi, I have a Vaillant heating system at home (Ecotec Plus, VRC470f, VR61) and because I've been repletely facing issues with the VR21 wireless outside sensor (dies every 2 - 4 years) I installed a wired VRC DCF (9535) to replace the VR21 sensor. The new sensor is properly installed and detected...