3rd system in 12 years

Sponsored Links
Surely advance appliances will honour their warranty and supply you with a replacement unit?

Quite possible to fit an external phe also.
But that modification would almost certainly void any warranty or guarantee.

I have spoken to them a few times and all they say is "it is quite old and we don't build them with internal stuff anymore"(I guess for this reason).
I am not sure what the warranty period is. I bought it in 2009.
A new one will be around £1200

If the internal phe is knackered, how would fitting an external phe stop the overpressuring? The internal knackered one is still there.
 
If the internal phe is knackered, how would fitting an external phe stop the overpressuring? The internal knackered one is still there.

The old one is disconnected. The old dhw tappings are plugged.
All the connections to the new phe become external.

Your warranty is probably null and void...


EnergyManager thermal store cylinder

It is important to have the cylinder serviced annually to ensure safe operation and as a requirement of the warranty. To qualify for the warranty a record must be kept in this guide.
 
Sponsored Links
Was kinda hoping it was a combi (passing filling loop would explain a lot) Its might be possible to cut out the internal phe and let it drop inside the cylinder then fit an external phe with pump and flow switch on to the existing dhw connections.
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Back
Top