Very basic cable testing question

Joined
15 May 2020
Messages
3
Reaction score
0
Country
United Kingdom
Please forgive my elementary question but I'm quite young and learning new DIY stuff every day.

Found a plug in electric mower being given away free - think it's just got a faulty power cable.

Tested cable resistance with multimeter by putting red probe on bottom left plug prong and black probe on brown wire at the appliance end. Fine, reading changes to close to zero indicating live wire is fine?

My main question pertains to the neutral wire (blue?). I put one test probe on bottom right plug prong - this is neutral? and the other on the blue wire at the appliance end of the cable - multimeter remains at 1 (i.e no change from testing nothing at all).

Does this simply mean that there is a break in the blue wire somewhere?

And secondly can I detect the break in the wire with an AM radio or by some other means?

Cheers all!
 
Sponsored Links
Right and left depends which way up the plug is.

Open the plug and put your tester probe on the end of the wire, not the prong of the plug.

This will bypass any defect such as a damaged plug, blown fuse, poor internal connection.

Did you know that the world's finest plug contains its own fuse? It will (should) be on the "L" pin of the plug, and the brown wire.

I doubt you will find a better way to locate damage in a flexible cable, than by making sure it is not connected, then running your hand along the cable sheath and inspecting it visually. If dirty, rub it with a damp sponge and WUL. Obviously it must not be plugged in.

On a mower, it has probably been mowed over, or possibly hit with a spade or other implement, or gnawed by a dog or rodent. These will all leave marks.
 
Thanks John. Looking directly at the prongs of the plug (not from the back). There is an L on the left next to the left hand prong.

The plug is sealed up so I can't get to the wires within the plug. The fuse has been tested and is fine.
 
Sponsored Links
No need to cut it off unless damaged and you suspect failure.

Put the crock clips on the blue connections and then wiggle the cable along its length to see if it goes to to zero.

However you don’t want to repair the cable half way down unless you have a
Tiny grass patch to cut.

You can get replacement flex for £7 on eBay

https://rover.ebay.com/rover/0/0/0?mpre=https://www.ebay.co.uk/ulk/itm/311977590676

Cut the green yellow wire off
 
Links in this post may contain affiliate links for which DIYnot may be compensated.
Thanks guys! eBay links very handy, have got some new cabling on its way!

Not quite a free lawnmower but pretty close!

Cheers again all,

Drew
 
Flex sometimes breaks close to the clamp where it enters the appliance, sometimes you can disconnect at the appliance, noting where its connected and simply pull on each core, and often one core pulls right out, you then simply cut off that bit often less than 200 millimetres restrip and reconnect
 
I love the simplicity of the OP's question and for asking advice.

Back in our day it was matchsticks in the socket. We didn't have the t'interwebs to ask for advice.
 
TBH I'd have shortened the current cable to enable the mower to be tested to see if it works before ordering a new cable.
 