3kw = 13.4A at 230v.
Except it was/is nearly always 3kW at 240v = 12.5A

3kw = 13.4A at 230v.

Words change meaning over time, when I was a boy "Decimate" meant to get rid of one in ten,
but today people seem to think it means 9 in 10 not 1 in 10.


Yes I guessed that but when was it removed, I thought perhaps it was a throwback to then.I think that trend came well after 1955.

A point of utilisation.I think that trend came well after 1955.
Point, in wiring.
Any termination of the fixed wiring intended for the attachment of a lighting fitting or of a device for connecting to the supply a current-using appliance.

"Every point shall be controlled by a switch..."
"Point.. termination of the fixed wiring for the attachment of a lighting fitting..."
That seems to imply every light should have a switch, but I'm sure the regulations didn't intend that.
In a commercial or industrial install, you'd have several fittings off one switch.
Even in a domestic install you may have two...

They must have, because that is what they wrote.Did they mean "Every point shall be controlled by a switch..."
Withdrawing the plug disconnects the supplyWould that not be true for any socket outlet, withdrawing the plug switches it off, I know at one time we had sockets which you turned the plug to turn it on, and pressed a button to turn it off, think it was a Reyrolle, used by GEC Large Steam Turbines, but the English is open to miss interpretation.

They must have, because that is what they wrote.
Regardless of what you think the differences are between "each" and "every",

I wish you'd explain what you think they did mean.Then they did not mean that one switch could only control one point.
Or switches.A single switch controlling every point in the installation would comply with that reg.
As per my first point...please do explain the difference.PS
It's not a question of what I think the difference is.


I had forgotten about that, little dash hound, did not like the vacuum cleaner, returned home to find the power cord, still plugged in and live, and in about 100 bits, dog it seems bit it, and it bit back, so dog really attacked it, how it survived I don't know, it was an electricians house (my father-in-law) so no RCDs in that house.it might save your dog`s life
If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.
Select the supplier or trade you require, enter your location to begin your search.
Are you a trade or supplier? You can create your listing free at DIYnot Local