  1. B

    testing off peak immersion

    sure its been done to death but its new for me . is their any way to test off peak immersion don't want to move cables to another consumer unit just want to know if their is an easy way around this
  2. B

    favourite small van

    I want to get rid of my Renault traffic and get a smaller van which do you suggest and why
  3. B

    remove soil pipe from floor

    thanks for your replys I didn't make a good job of explaining what I want to do I need to remove 10cm of plastic pipe fill it with 5cm of fire stopping and 5cm of screed
  4. B

    remove soil pipe from floor

    I have to cut out a plastic soil pipe out of a concrete floor does anyone have an ingenious way that doesn't involve smashing my thumb a bit late for that im afraid
  5. B

    calculate vent pipe height

    the linear expansion of water is 0.000207 /*c I have used delta t 65 height 9000mm I,m not sure if that's the correct expansion rate will sorry if im a bit abrupt for you dan it,s not intentional its just part of my charm
  6. B

    calculate vent pipe height

    the vertical height is 9m cyl to cwst the temp is 4*c to 65*c how much above the cwst does the pipe need to be
  7. B

    basin height

    just a quick one haven't fitted one for a while used to fit them at 31 inches is it still the same
  8. B

    speedfit in concrete floor

    does it need protecting against the cement I know copper does but I don't know if the layflat stuff does
  9. B

    saniflow plus up

    thanks again I think I,ll go with your suggestion as I,m going to glue most of it
  10. B

    saniflow plus up

    thanks a lot that a bit like what I expected the builder only wants it too work how long is optional I think in copper is better as a pulled bend will give a better radius
  11. B

    saniflow plus up

    been ask to fit saniflow plus up the pipe is in 22mm out of the saniflo is it best to increase the size to 35 or keep it at 22 the doesn't conform to the best practice as it will have to run 2m horizontally before the vertical section the builder who wants the work says it has to be like that...
  12. B

    boss in cast iron stack

    i want to fit a boss to a cast iron stack as the existing sink boss is too high anybody done this
  13. B

    marks on china

    I have a porclean rubber for removing marks mainly wedding ring marks or screwdriver marks off whb or wc,s but I thought I would ask if anyone knows of a better way as the rubber uses a lot of elbow grease
  14. B

    tv interfearance

    I am going to spend some time tomorrow checking weather or not he has planning permission however winston1 you state he almost certainly has planning permission how do you know that ?
  15. B

    tv interfearance

    we have an irregular loss of tv which rightly or wrongly we think a local guy has an ariel for a cab firm which interfears with our reception q1 is this likely there is an ariel approx. 50ft high at a house about 75ft away q2 can I buy a suppressor to stop this problem (I think I have a high...
  16. B

    straighting 10mm pipe

    just interested in how people do their rolls of copper tube I unroll mine on the floor steady it with my feet and try to let the weight of the roll straighten it I was just wondering if theirs a better way
  17. B

    lack of water

    I am helping a friend (also a gsr plumber)fit a 300litre unvented and 30 kw heat only boiler he has done all the plotting and planning and its his job but the incoming sevice is about 10litre per minute and less than 1 bar so what are his options I saw him discuss a booster tank with the client...
  18. B

    Power issue to central heating control unit

    I am always grateful for help I just wanted to know if anyone found carrying a meggar useful or is it just another tool to take up room without any real value I know how I usually find these and it should only take two fuses so I can buy a lot of fuses for the price of a meggar
  19. B

    Power issue to central heating control unit

    could you call me a know it all too, I tired of being called stupid like the scarecrow I borrow other peoples brains someone must have said too me get a multimeter with continuity resistance and volts but not pnp transisters capacitance et al cause you don't know what your doing and you don't...