Search results

  1. coolhands

    Continuous water noise greenstar but no leak

    I have a Greenstar 25si Worcester. Both the hot water and heating work ok. The problem (just occurred) is I have a continuous running water noise most apparent from the hot water (taps) outlet pipe under the boiler. I eventually traced it to that using long screwdriver to ear. When I shut the...
  2. coolhands

    Greenstar 25si not responding to call for heating after powercut

    Hi as title with DT20rf control panel and a wireless thermostat in the hall. We had a power cut and now even though the thermostat is calling for heat, the boiler is not doing anything. I've checked current time, date etc and all settings, everything is normal & correct. The boiler does ignite...
  3. coolhands

    Adding ikea LED lighting from cooker hood supply

    Hi A recirculating cooker hood is going to be installed between two wall cabinets in space shown, using the ring extension behind that backplate (it does not come off the oven supply). Originally that was to be its only function, but, I now also want this to supply ikea led worktop lights for...
  4. coolhands

    How to extend wire to fit end of ceiling light track

    I Want to fit a 1.2m lighting track to my kitchen ceiling. I believe the wire connection is to the end of the fitting. But the ceiling hole I have would be mid-way along the track ie in the wrong place. What is the best / neatest solution to extend the wire to the appropriate location? I don't...
  5. coolhands

    RCCB tripping when changing socket with power off?

    I switched the MCB off to change the cooker socket to a new one after decorating. I checked power was off with fluke tester shown in pic. During the process the RCCB tripped. I cannot fathom why if the power was off. I was pondering it while working, and thinking about the odds of it happening...
  6. coolhands

    Recommended way to add power cord to socket where plug won't fit

    I want to plug in a power cord. But the plug socket is behind a unit so there is no space for the plug. It is a 2-gang socket so I can't use a flex outlet plate. Am I allowed to remove the plug socket and connect the wires inside a maintenance free junction box such as the Ashley J803 leaving it...
  7. coolhands

    What washing machine spigot to attach to 32mm solvent waste?

    I have created a new waste out of 32mm solvent weld. I have used all Hunterplastics items for this, which are nominally 32mm (actual 36mm). (I know it is possible to join compression pipe to solvent pipe by using a straight compression fitting). So, I have a solvent weld upstand pipe for my...
  8. coolhands

    what constitutes a new circuit?

    In my own home am I allowed to add an extra socket on the ring main? (no actual increase in number of sockets since I will be removing an unwanted one. So in a sense re-siteing a socket I suppose). Am I allowed to rewire parts of a ring circuit to remove inaccesable junction boxes fitted by...
  9. coolhands

    How close to these downlights can I put insulation?

    Haven't got a decent pic but the flat downstairs has had new downlights fitted recently you can see two of them in this pic. I assume they are fire rated. I intend to put Rockwall Sound insulation between the joists. Although rockwall is non-flammable I assume I need to leave some clearance...
  10. coolhands

    Best combi boiler? Popular, reliable, compact

    as title. Since my potterton puma 80 is getting old, I'm going to start planning for replacement. Top wants on my list would be a boiler that is reliable, well made, popular (so common faults will be well known amongst plumbers) and compact - it is for a very space-limited london flat, so...
  11. coolhands

    Am I allowed to change flow switch on potterton 80?

    legally? I have established I have the problem of the dhw flow switch sticking on (causing overheating and lockout) so it needs changing. Am I legally allowed to change this? I am not a heating engineer or gas safe. Not sure what the legal position is these days, years ago I would have just...
  12. coolhands

    Am I allowed to replace this junction box?

    I'm changing my kitchen and noticed this junction box screwed to a joist under the floorboards. I know they are meant to be accessible and this isn't. I am just asking if I am strictly allowed due to laws etc. as I don't know so thought I'd ask. I would replace with WAGOBOX and connectors.
  13. coolhands

    can / should I add extra earth bonding?

    my flat has a modern consumer unit fitted before I bought the place. It has some earth bonding to some pipes, but not many. Should I (am I allowed?) fit further earth bonding between all pipes eg the boiler which is in a cupboard in the bathroom not all the copper pipes are linked, the bath is...
  14. coolhands

    I've got 46 volts between black wire and earth

    hi. In my communal hallway there are time delay two way switches. One of them burnt out from being stuck on so I decided to swap for new. However, although the light works when connected up as before I observed the back box was 'live' when touched with cheap electric screwdriver so I...
  15. coolhands

    2-way hallway switches have 120v & 50v

    hi in my hallway there are two switches so the light can be operated from either end. I will add pics shortly. But with all the wires separated, there is 120v between live and neutral, and 50v between live and earth. I have not looked inside the ceiling rose yet. what could cause this...
  16. coolhands

    Water leaking past front door weatherboard - suggestions?

    Hi all hopefully someone can give some advice... The front door to our house is at the top of some concrete steps. At some time in the past, the top step has been screeded(?) over for an unknown reason - this may be adding to the problem. Basically the rain is blowing under the weathboard...
  17. coolhands

    Leaking down from extended party wall / chimney - pics

    Hi WE've got a leak! I assume this area was once 'fillets' that have in the past been concreted over (probably due to leaks) and I would imagine this is where our leak is now coming from? - When it rains, rainwater almost immediately starts to run down the chimney breast in that attic room...
  18. coolhands

    Sliding sash window restoration - double glazed units

    ok any recommendations who to use? I want to replace the sash windows in my flat (originaly single pain units at the moment) with double glazed units, but retain the original boxframe googled sash window double-glazed providers: http://www.sash-restoration.co.uk/index.html...
  19. coolhands

    What would cause this melted switch? (pics)

    This switch is outside the bathroom on the wall and switches on / off the electric shower (9.5kw from memory). Thing is it's been in service for about 9 or 10 years! So why now would it suddenly melt? It has never got wet or anything. The shower was replaced about a year ago and is working...
  20. coolhands

    connect both ends of my armoured cable (shed)

    I got a quote from an electrician he is quoting as above. I have already run 6mm2 armoured cable from the cu under my stairs to my (permanent) shed /workshop. + 1 light and 1 socket. I even have the correct siemens breakers ready, and mk garage cu already purchased. I simply have not...