Search results

  1. T

    Flexable gravel grids/stabilizer

    Has anyone used and or got any opions on the honey comb style expanding gravel retaining systems like those pictured below for use on gravel driveways? I've only seen it used in subbase on large soft areas but they seem to be selling it as use on driveways.
  2. T

    Solder onto warrix flange

    Can I solder straight onto the warrix flange or do I need to use compression joints?
  3. T

    Connecting 32mm to 15mm water meter

    The water board is telling me I can connect up to 32mm pipe to their 15mm water meter and it should not reduce the flow. But this does not sound correct to me. Is this correct or do I need them to fit a larger bore meter? Currently the property has a cast iron feed on the property side and...
  4. T

    3D Textured Wall Panels

    I've seen lots for high end textured wall panels in commercial buildings, I've never seen them in domestic properties. However I came across, on ebay, listings for compress bamboo fiber panels which are considerably cheaper than their commercial counterparts. So I was wondering if: Anyone has...
  5. T

    Silicone smear UV resistance

    Hello Is a silicone smear on the external pane enough to protect an exposed sealed unit's edge (hot melt)?
  6. T

    Removing hipped bonnet tiles

    Is there a knack to removing hipped bonnet tiles which have been bedded in with mortar? Other than smashing them to bits that is.
  7. T

    Sloped Flitch beam

    Can I slope a flitch beam between 2 timber wall plates at about 5 degrees?
  8. T

    Clipper MTA36 power float hydraulic recharge

    Hello My clipper mta36 power floats release valve o rings have gone and made a puddle of hydraulic fluid on the floor, how do I reprime the system. I presume I add oil to the reservoir and pump with the valve open to get rid of any air but how do i know how much to put in?
  9. T

    Block and beam wall plate

    Is there such a thing as a wall plate for block and beam t beams and if not why not? I am not talking about for new walls but for tying into existing walls. (timber suspended floor wall plate)
  10. T

    Move wall plate to fit UB

    Is there a way to move the wall plate to the right(and up) so I can move the UB up? The new UB etc would protrude 250mm into the rooms head height.
  11. T

    Floor level 1m below existing dpc

    How would you go about detailing the dpc/DPM on an extension where the ffl was set 1m below the existing dpc? So there would be internal steps down from the existing floor to the new floor.
  12. T

    7n block ontop of 3n

    Just checking this as someone pointed this out to me an now it's got me thinking. If your second floor is greater than 2.7 meters you have to use 7n blocks however I can't see it written it has to be the full wall that has to be 7n so in theory your ground floor can be 3n blocks. Is this correct?
  13. T

    Rigid and mineral cavity fill

    Can both rigid and mineral cavity batts be used in the same cavity, so for example 125mm cavity 75mm kingspan 50mm dritherm? The mineral batt would keep the pir tight to the internal skin no danger of bridging cavity with snots etc.
  14. T

    Timber frame cavity insulation

    Just reading though the kingspan literature for insulating a new timber frame building and it says you need to leave an air gap between the outer sheathing. Why is this recommend? The osb sheathing will act like a vapor barrier so the back side don't breath will it? Is there a way to fully fill...
  15. T

    Concrete over fresh slab

    I've just poured fresh slab my slip sheet failed and pushed the insulation and mesh up. Instead of ripping it all out I am planning to recast a new 100mm slab on top. Do I need to wait until the original slab is fully cured? Can I get away with something else?
  16. T

    Flat roof extenion on a doubled hipped roof

    Hello Has any one got any pictures/drawings/insite into how to attach a flat roof to a doubled hipped roof when the flat roof is taller than hipped sofits? I can't picture what happens at the corners as the new roof would be higher than the roof line on both faces. Bit like below but flat roof...
  17. T

    Stepped foundations with SCC

    This might seem a stupid question but can you do stepped foundations with scc or will it just run everywhere?
  18. T

    DIY watertight concrete slab

    Is there a concrete additive for slabs which does away with a dpm? I know if I get ready mix I can get structural waterproof concrete but all the liquid stuff I've got says not suitable for structural concrete.
  19. T

    UFH Manifold in loft

    In a bunaglow can the UFH manifold and pump be sited in the loft and the zone pipes run down walls to floor? Head would be max 2.7m
  20. T

    Rough costs for sewer redirection

    I know this is a long shot as there is not really enough information here to give you the full picture however I am looking for ball pack figures for redirection of a public sewer servicing 3 properties. Black is existing, red is proposed, there is a scale on there (the house is ~15m long)...
Back
Top