Search results

  1. C

    Choosing not to insulate?

    (Not sure if this is the right section!!) As discussed in another thread, I am building a 30m2 garden office. Assuming I figure out how to build the floor, this question is about not bothering to insulate it. I appreciate the implications this has for subsequent building regulations approval...
  2. C

    Floor framing

    So, the Aim of the Game is to build a 6.6*4.6 Garden Office – timber-framed, off block piers. I thought I knew what I was doing, then had a look on YouTube and got myself confused! This guy made something 6.5*5 by breaking it into six equal size boxes (obv. about 2*2.5 each). He first screwed...
  3. C

    200kg Stove - Tilt into a Berlingo?!

    Hi, Not sure which bit of the forum, if any, is the right place to ask - but here goes...... I need to get a 200KG stove from Glasgow to Devon, where i am. The problem is that it isn't on a pallet. I have found a man/van team that can get it on a pallet for a freight-team to collect, but they...
  4. C

    Strength - 90 or 170 timber, vs blocks

    Evening, I'm planning a garden studio, and was thinking of timber-framing - until i got worried about how solid it would end up feeling. Would 170mm carcassing, at 600mm centres, create a much stronger final building than 90mm? I'm also worried about the sense of strength. For example, if...
  5. C

    Garden Office - existing foundations

    Hi, I want to replace a tired shed, measuring about 2.5 metres by 5 metres, with a larger garden office. The existing timber structure stands on a brick footing, itself on a concrete plinth. The plinth extends beyond the timber frame by about 0.5 metres, but doesn’t look terribly flat. For...
  6. C

    Flange - for horizontal hot water.....

    Should i fit an Essex or a Surrey flange - or one of the more obscure alternatives - for a horizontal hot water cylinder? There is a decent head from the cold water supply, but still poor flow at the taps. I am thinking this might be because of air being drawn in, but was thinking of fitting a...
  7. C

    Floor - level enough?!

    Laying engineered flooring in an old house, solid floors but seriously uneven. How level do they need to be? For example, on a 1800mm level i have a 4mm depression for 660mm around the middle. Is that the sort of thing that glue can tolerate? Or SLC everything and everywhere? Cheers Crawf
  8. C

    Wood flooring: bouncing, not floating

    Evening, Pretty sure folks are going to enjoy telling me that this situation is a hopeless disaster, but here goes...... The 50m2 of engineered wood floor we recently laid to float on 5mm foam underlay is bouncy in places: clearly, the underlying substrate is not perfectly flat. Is the best...
  9. C

    Electric UFH, Wooden Flooring and DPM - Fixing?

    Hi, Looking to fit wooden flooring over electric UFH. Substrate is a mix of concrete and timber, with moisture of <2% - but might not stay that low, so thinking a DPM would be a good idea. Is it better to float on a DPM/underlay Or, glue down a plastic DPM and then glue flooring onto it...
  10. C

    PIR + Plasterboard?

    Evening, Can i fix PIR insulation to rafters, then drill through it to secure plasterboard? If i use 75mm PIR, that seems like using long screws for plaster board - can they be standard ones, rather than plasterboard ones? Perhaps with washer's to stop the heads pulling through the board? I...
  11. C

    A nail - holding up the rafters?

    Hi, Is it likely that the lower ends of roof rafters have been simply nailed to the wall-plate? Picture A shows the general appearance, Picture B the nail. I was expecting something like a Bird’s Mouth joint, as I can’t see anything else serving the function of a tie-beam. The room is 2.5...
  12. C

    Kitchen-sink: space needed for plumbing?

    Hi, How much space is needed for plumbing under a kitchen sink? I ask because I have a space 143cm wide - and want to cram in three things: the sink, a fridge and a dishwasher. Would it be possible to get extra cupboard space by mounting the sink on the work-surface itself, rather than in a...
  13. C

    How to roof this?

    Hi, Reckon i'll get criticized for this, but how should i go about roofing this extension? I was thinking of an RSJ along the long dimension, with perpendicular exposed timbers - then I realised how heavy that would be. The window means that i'd prefer to avoid a pitched roof. The house...
  14. C

    Drain and p trap?

    Hi, How many drain pipes can connect through a single p trap? I was planning on a single drain pipe carrying the waste from three toilets and two showers, passing through a p trap before the inspection chamber. The trap suddenly looks pretty small, and likely to get blocked by toilet...
  15. C

    Bathroom floor thickness?

    Hi, How thick should the marine ply be on a bathroom floor fixed at 400mm centres? I was thinking that 25mm would be more than enough...... However, a wet-room supplier tells me i will need also 6mm cement board on top of this too to prevent bending. This seems excessive to me. We only had...
  16. C

    P trap AND air admittance for drain?

    Hi, I currently have a ceramic pipe leading into my main drain inspection chamber. It is fed by a combined soil pipe and waste water inlet which includes some sort of old P trap/bottle gully. As part of fitting new toilets, I am adding a new soil stack. I want to connect this to the existing...
  17. C

    1960s Drains - how best to add new connection?

    Hi, Looking for some advice on how best to add a new connection to my existing 1960s drains - and where best to put the waste stack. I've tried to draw the layout below. Essentially, there is a manhole cover and inspection chamber about 1.5 metres from the house. This is currently fed by two...
  18. C

    Gender questions - for a hot water cylinder

    Hi, Looking for some advice on fittings for vented hot water cylinders…… For the coil, 1” male seems standard – would changing this for either a 22mm or 28mm compression fitting be £20 well-spent?! Similarly, I can change the gender of the cold-feed and the hot-water draw-off from female to...
  19. C

    Wood-burning stove - buried air supply?!

    Hi, Not quite sure if this is the right section to ask in, but here goes....... We are just about to order a stove and, before the installer arrives, i want to sort out the constructional hearth. This raises a couple of questions..... 1. Our chosen stove, the Contura i5, requires an "air...
  20. C

    Beam between internal walls?

    Hi, I am renovating a cob cottage, and would like to increase the head-height over the first part of the main staircase. Removing the plaster has revealed a beam, which crosses between two internal walls, which is the problem. The first question is why is the beam there? The second question...
Back
Top