  1. M

    Drayton Wiser app update 6.9.0 and hubr 3.18.0

    Has anyone updated their app to todays release (6.9.0)? I have and its rather underwhelming! We now have signal strength indicators for all the devices and a dark mode. Glad to see Schneider app development team haven't been totally sitting on their hands all these months, its a shame we still...
  2. M

    2port zone valve wiring connections?

    I have a couple of Honeywell 2 port motorised valves on my s plan system, one is a 5 wire and the other is a 6 wire. Both valves work ok so I don’t have an issue but I am a little confused as to why all the online s plan wiring guides I have seen show the grey wires going to live and the orange...
  3. M

    Sunvic immersion thermostat

    Hi everyone, I need to replace my immersion thermostat, it’s a Sunvic VKL2401. I have found a couple online from companies I am not familiar with so does anyone have any good sites I can order from. Thanks
  4. M

    WB Greenstar boiler technical info required

    I have a Worcester Bosch Greenstar 24i system boiler (GC Nr 41-311-68 NG), I am searching for technical information regarding exactly how this boiler works specifically how the various connectors on the PCB communicate with external controls. The installation and commissioning manual has some...
  5. M

    Bosch Easycontrol on Greenstar 24i

    Has anyone installed the Easycontrol on a Greenstar system boiler wired s plan? I’m just trying to understand how the system would need to be rewired. Thanks
  6. M

    Honeywell 2 port zone valve question

    I’m investigating an issue where randomly when my CH thermostat stops calling for heat the boiler and pump (it’s a system boiler) turns off and I hear a pipe knocking with a single thud somewhere in the ceiling. This happens whilst the pump is still in overrun and doesn’t happen all the time. My...
  7. M

    Worcester Bosch Greenstar boiler minimum flow rate?

    Can anyone tell me the minimum CH flow rate for a Greenstar 24i system boiler (GC Nr: 41-311-68), I've searched the Internet but can't find it. Thanks
  8. M

    Bath tap spares

    Is it possible to buy spare parts for taps? I have an issue where corrosion has nearly destroyed part of my bath taps (see pic) but replacing the whole tap is going to be very tricky. It looks like the chrome corroded part will unscrew.
  9. M

    Wifi control of electric heaters.

    I want to be able to remotely control a couple of electric wallmounted heaters, 1kw and 1.5kw, which at the moment have removable built in programmers. I have found the following on Amazon...
  10. M

    Searching for a deadbolt

    I want to improve the security of my main door by adding a double locking single cylinder deadbolt but I can't find any suppliers, does anyone know of any suppliers that meet this criteria? It needs to be double locking as the internal housing could be accessible through the doors letterbox...
  11. M

    Boarding my loft options

    I am presently increasing the thickness of loft insulation to 270mm and have an area where I need to lay additional loft boards for storage purposes. I have a trussed roof which I believe is rated for 25kg/m2 but now that it gave the chipboard sheets and the 175mm x 47mm wood battens I have...
  12. M

    Karndean gaps between tiles

    Several years ago I had Kaendean tiles laid over a chipboard floor in the utility room. The issue we have is that over time a small gap appeared between the tiles running down the centre of the floor, the gap varies between tiles and is between 1mm and 2mm. Other than pulling up the tiles is...
  13. M

    Screw sizes for loft boarding project

    I will soon be boarding my loft and need a bit of advice re screw sizes. I will be battening the loft with 175mm x 47mm battens and laying 18mm chipboard on top, what size screws would be recommended to screw the battens to the 3xisting ceiling joists and the chipboard to the battens? Thank you.
  14. M

    Leaking radiator valve

    On the attached photo does the end cap screw off or should it just flick off? Thanks
  15. M

    Central heating shock arrestor?

    For quite a while now I have had issues with water hammer when the central heating pump turns off. This is on a pressurised system with a Worcester Bosch Greenstar 24i boiler. I have seen that you can buy shock arrestors for water hammer but they all look to be for cold water supply and not...
  16. M

    Fused spur timer on a 1.5kw heater.

    I want to add a timer to a 1.5kw electric panel convector heater (Dimplex EVS150), is the timer in the link below suitable? Thanks. https://www.timeguard.com/products/time/immersion-and-general-purpose-timeswitches/7-day-fused-spur-timeswitch
  17. M

    Viva Skylo bottom fill valve

    Fitted a Viva Skylo bottom fill valve to our downstairs cistern and I found a piece of blue plastic in with the instructions but nowhere does it say what it is for. Any idea?
  18. M

    flexible braided hose to connect 15mm isolator tap to fill valve?

    I am installing a new fill valve to a cistern but I can not find anywhere that can supply a 30cm braided hose that will fit the fill valve and the isolator tap as per pic, I am replacing the copper hose in pic. Anyone know where online I can get the hose?
  19. M

    Conservatory roof replacement

    The really cold weather this year has spurred us on to look at replacing our glass conservatory roof. The conservatory electric heaters are costing a fortune as they are basically on 24 hours a day just to keep the room at 15c and if we turn them off the temp drops to well below 10c in just 30...
  20. M

    Drayton Wiser app v6.1.1 issue - Solved

    Anyone with the Wiser app be aware there is an issue where you can no longer use the heat reports. The room selection is missing.
Back