Search results

  1. M

    Bit of a odd one

    I had to replace a radiater today on a gravity fed system, i used the rad valve plugs on the expansion and down pipe to plug system like i have 100s of times and long story short the tank is filled but doesnt seem to be filling the pump. I took off the pump and it was dry both sides so im...
  2. M

    ABS problem

    Hi , i have a 1997 golf TDI and the ABS light is on since 2 days ago. At one point for a matter of seconds it felt i lost braking altogether!! Does anyone have any ideas of what this problem could be? Thanks
  3. M

    Dunlop or Bal

    Im going to tile the kitchen floor which is wooden, which im going to use Dunlop fast set stuff. I normally use Bal gear. My question- Basiclly is Dunlop still good stuff?
  4. M

    baxi no hot water

    Hi , I have a Baxi boiler and though the hot water is flowing it dosent seem to be getting hot. The important part of this is that the 60 degree setting is flashing.......any ideas? EDIT[ pressure is at 1.1 bar :wink:
  5. M

    Any newly registared CORGI people out there?

    Im getting diffrent information on what CORGI want as entry requirements. As far as i was aware you needed a minimum of 80 hours under a CORGI installer but when i asked CORGI about this today it wasnt the case. Can anyone confirm this? also any other info on what are good books to read...
  6. M

    Advice on gas training

    Hi, im a kitchen/bathroom fitter and would like to install gas hobs and cookers. im aware of the ccn training and the elements that need to be covered. When i complete this training would it be possiable for me to have my corgi assessment? Any advice will be great .... Thanks
  7. M

    Would like to learn more please

    Good mourning! :P Can someone tell me how i can work out how many l/v lights can go on a transformer and how to work it out with the transformer ratings etc. Also im intrested to learn more about light dimmers and how to work out wattages with diffrent lamps etc. Thanks
  8. M

    picture anyone?

    hi, has anyone got a picture they can post of a RCBO wired in a board ? i havent done one before and need one to cover alterations to a light circuit.
  9. M

    Worscter heatslave 924

    Hi i need some advice on this boiler. I need a new heat diverter valve fitted. is this something i can do? (im a plumber but not corgi) and is it quite easy to change. Thanks Steve :wink:
  10. M

    latch not turning

    Hi , I had problems with the handle on the bathroom window and so i took the handle off and i think i need to replace some bits inside. problem is that i cant open the window to look inside to see what i need to buy. Im quite able to fix this if i can get the window open :lol...
  11. M

    S in ZS

    i know the Z stands for impedence but what does the S stand for? is it system? does anyone know :?:
  12. M

    NIC toolbox

    Hi , Mate of mine ordered a new NIC toolbox a week ago but still hasnt recieved it yet. I hear that they have stopped making them. Is anyone in the same situation?
  13. M

    Broke my megger 1552 lead

    Anyone know i a good place to buy new ones? Got my NAPIT inspection soon :) GS38 and all that!
  14. M

    Insulation resistance for periodics

    Hi, Ive heard you can do a insulation resistance test by short the live and neutral together at the board, then tests to earth can be written as limited. Sound right to you.? also how would you go about this? EDIT Any views would be welcome
  15. M

    plastic pipe MDPE

    Hi, Im replaceing the lead pipe at father-in-laws house. Am i right in saying its 25mm MDPE pipe thats needed? Ive seen 20mm and 35mm aswell but i thought 25mm was the norm??? Thanks :)
  16. M

    TT or TNCS

    I went to see a job today .The installation was what i thought to be TT however the 100ma and 30ma was nowhere to be seen. I guess it was wired early to mid 80s. The TT electrode termination was a bit loose. What confused me a bit was where the cutout was (bearing in mind it wasnt your normal...
  17. M

    Replaceing lead

    Hi , im going to fit father-in-laws kitchen over the next week and am going to change his main incoming lead pipe. Im going to rip out and join under the floor at the boundey (as close as possiable) because the lead pipe goes out at a funny angle down a few door steps. Question is i...
  18. M

    city guilds 2360 level 2 course

    Hi, Does anyone know if you can study this course online anywhere? cheers mst
  19. M

    RCBO prices

    Does anyone know of a place where RCBOS are below 30 pound?
  20. M

    socket and see testers

    Hi, A sparky mate of mines megger has just given up on him and he says hes going to buy socket and see test kit. does anyone know what there like. Thanks