  1. D

    Limits of a special location - 701.32.1

    On an EICR I discovered a bedroom that had a small shower cubicle installed in the corner of a bedroom. The shower screen and shower door fully enclosed the shower. The screen was 2.25M high. The adjacent walls in the corner of the bedroom completed the cubicle. There are sockets in the...
  2. D

    Maximum Demand for a church

    A builder has asked me to look at a kitchen refurb he is doing at a church. In the new kitchen there will be a 6KW water heater for the sink, a 6KW tea making machine, 3 x 3KW plinth heaters, and a 6KW water boiler/cofee machine. Along with the usual lighting and sockets there is a 4.7Kw...
  3. D

    HF Intermittent lights

    Scenario is 4 double and 2 single flourescent light box fittings in a suspended ceiling. The lamps are PLL 4 PIN COL840 55W. (240V) They are all fed from one gang of a standard 4 gand light switch. They intermittently stay off, come on or flicker together. Would you suggest it is the...
  4. D

    In between self levelling depth and screed

    I need to Level a concrete floor in a room I have knocked through into up to 25-30mm which seems to be in between screed and levelling compound. Any ideas ? could I build up with say 20mm plywood screwed to concrete and level over that ? Could I build up with some form of insulation ...
  5. D

    BT Versatility wizard

    Hi does anyone have a copy of the above software ? Doesnt have to be the very latest version but would like to connect to a system I am trying to configure Thanks
  6. D

    BT Versatility Music on Hold

    Hi, i have acquired a used BT versatility system and am ready to install it. I am pretty confident on the standard set up and how to wire the extensions and configure it. In terms of enabling MOH, it seems I need a MOH module and also an options module (which I dont have but seem readily...
  7. D

    Anyone dared test an RCD this way ?

    I'm just curious, but has anyone deliberately or accidently touched a live supply and tripped a 30ma RCD, and if so, did they feel a shock before the RCD operated ? Theoretically it should trip within 2/10 of a second at 30ma fault current and usually around 25-40ms so I would expect it...
  8. D

    Ban All Sheds or Ban Ban All Sheds

    I find the sheds that ban all sheds would like to ban to be in the most part convenient, useful and helpful, and are becoming increasingly good value. However, I find that ban all sheds is in the most part tedious, boring and unhelpful, and is becoming increasingly irritating. You can...
  9. D

    How to wire a JB

    May sound a daft question, but how do you do it neatly and quickly ? I have found the best method for me is to strip each T&E cable, cut the individual cores to suit its entry point, and terminate one cable and one conductor at a time, lightly tightening the screws, and then adding each...
  10. D

    Getting one back on the distributors - very useful info..

    I had a board change yesterday where the supply was overhead , the fusebox was earthed using the incoming gas (actually a good earth at 75ohm!). The service head was PME. I called central networks "PME team" (after 10 minutes of going round the houses), and asked if the supply has been...
  11. D

    The Price is right ?

    I was asked to provide an estimate for a ground floor extension/garage conversion + kitchen refurb: Kitchen: Supp. & install: 8 x firerated cast GU10 downlights (6 main kitchen, 2 extension) approx 4 New socket outlets where required; Switched spurs for extraction fan & hob ignition, washer...
  12. D

    32A C-Form Sockets

    Do these come in single phase ? The requirement is to provide a 32A and 16A supply for a Wedding Marquee. My intention was to install a small unit in the garage (fed from an existing 45A switch fuse) with 100mA RCD main switch and 2 ways, 16A & 32A to a board adjacent with c-form socket...
  13. D

    Neat Alarm Panel Wiring

    Any top tips to make the wiring inside the panel neat (been using Accenta G4 compact) ? I have wired a couple and haven't been satisfied with the outcome in terms of tidiness. Main problem caused by having to use chock blocks to wire tamper circuit in series and to connect the multiple...
  14. D

    Accenta G4 false alarms and double knock

    I have installed Accenta G4 panel with 2 PIRs, one in a portacabin used as an office (zone1), the other (zone 2) in a big wooden shed/workshop which is drafty/may have rat vistors ! Zone 2 alarmed, at 0530 a couple of days after installation. There had been no (human) entry. After reading up...
  15. D

    Accenta Gen4 Tamper Lockout

    As the subject line implies, I have a tamper lockout on newly installed alarm, with just two sensors, bell and 1 remote keypad. I have tried to link out the tamper circuits to the bell (TA) , the RKP (TAMP) on the left side of the panel, and the main tamper loop TAMP terminals. What I found...
  16. D

    Additional Consumer Unit

    A large extension (utility, kitchen, cloakroom, dayroom, 2 beds, 2 ensuites plus garage) The existing CU has no RCD. Proposal: From meter tails install henley block and 60A switch fuse. From switch fuse run 16sq mm 3 core SWA 7 Meters to IP65 box along outside wall. Within IP65...
  17. D

    Smoke Detectors Certification

    As well as the BS7671 certification for mains powered battery backup smoke and heat detectors, my local building control are requesting a BS5839 certificat for new installs. I have never issued these, although I have a pad from the NICEIC. The sticking point is the entries required for sound...
  18. D

    Structured Cabling RJ45 adapter

    I've recently installed some CAT5 structured cabling. BT have terminated 10 phone line pairs into a krone strip. I have cabled fom here to an Rj45 patch panel, each pair into pins 4 & 5 on each outlet. When I connect a phone via an RJ45 adapter into the patch panel, I get dial tone and can make...
  19. D

    Grid Switch Questions

    I am installing an 8 gang grid switch in a kitchen, never fitted one before. Its supplied via a 32A RFC in 2.5 T&E. The loads will be Dishwasher, Hob Ign, Ext Fan and Under Cabinet Lights. The design is 4 DP switches below 4 fuse units, (13A for D/W, 3A for rest) First question: Do you bring...
  20. D

    Strange Neutral Earth Fault

    Its a TT supply with 100mA time delay incomer RCD, and ordinary 30mA RCD. The lights and cooker are on on the 100mA RCD side of the board, and the sockets on the 30mA side. I installed the board to replace a rewirable months back. All insulation tests >500M at the time. I got called back as they...