Wiring mains powered wireless smoke detectors

Joined
18 Aug 2010
Messages
1,012
Reaction score
27
Location
London
Country
United Kingdom
Hi there.

Before I can get my recent loft conversion signed off by building control I need to satisfy the fire regs.

One of the options is mains powered and interconnected (can be wireless) smoke detectors in the habitable rooms.

My concern with this option was hacking the ceilings of rooms. Having looked at some of these devices on line I see they can be powered from a local ceiling light rather than running a whole new electrical supply there.

If I can get to the wiring of the light in each room by lifting the floorboards of the room above would this mean these could be installed without any hacking of the ceilings?

In other words all done from the floor space of the room above?

Thanks very much
 
Sponsored Links
If you have access to a floor void above the ceiling then conventional hard wired mains interconnected smoke alarms can be installed without damage to your ceiling.

Have BC asked for one in every habitable room?

Is this just a standard house with a loft conversion, or is it a HMO?
 
If you have access to a floor void above the ceiling then conventional hard wired mains interconnected smoke alarms can be installed without damage to your ceiling.

Have BC asked for one in every habitable room?

Is this just a standard house with a loft conversion, or is it a HMO?

Thanks.

I can access the void space but using wireless would still make life a lot easier. Getting power from the local light circuit is one thing but hard wiring all the detectors together across different floors of the house would be a lot more work.

It is just a domestic house not hmo etc but BC have asked for this in every habitable room. They do give other options like changing all doors to habitable rooms to firecheck doors. However since it is a period house I would really like to retain the original doors.

Thanks for your advice.
 
Aico do a hard wired , wireless interconnected smoke/heat detection system. As you note you need to get a supply form a light fitting. But not to each other.
Fine on a domestic, dubious on a HMO IMHO.

They also do a all battery system wireless interconnected.

Easy to install and no mess.

Check to see if this is allowed.
 
Sponsored Links
Also, you'll need to find out how your lighting circuit(s) are wired. There's not forced to be a permanant live at your light fittings.
 
Battery powered is not acceptable to BC I'm afraid.

I don't understand what you guys mean by the no 'permanent live' at the lights comment.

Are you saying there might not be a live wire feeding the lights??
 
yes. you might have switched live, meaning if your light switch is off you have no power at the light fitting - thats what i think anyway.
 
Ok, I see what you mean now :)

I suppose it's unlikely that all lights to all rooms on the first and ground floor would have a permanent live then?
 
I suppose it's unlikely that all lights to all rooms on the first and ground floor would have a permanent live then?

It's probably quite likely there is a live and they are wired loop-in but better to check.
 