Search results

  1. X

    compression fitting all way in

    Do compression fittings need to have the pipe pushed all the way in. Or is just past the back end of the olive enough?
  2. X

    Conex iso valve

    Does anyone know were they sell conex iso valves in 15mm?
  3. X

    cross over bend between too points

    Hey I can pull a bend as in the picture but how do I make it so its a set distance been the two ends of the pipe? That will be going in to elbows?
  4. X

    fitting washing machine how tight connections

    When tightening the connections on a washing machine is hand tight all that is required. Or is say half a turn with a pair or grips needed?
  5. X

    Storing flux in the van

    Can flux be affected by heat when stored in a van?
  6. X

    flux brush

    Is any.type of brush ie paint brush etc ok to be used as a flux brush or does it need to be a specific flux brush?
  7. X

    flux brush

    Is any.type of brush ie paint brush etc ok to be used as a flux brush or does it need to be a specific flux brush?
  8. X

    supporting bath waste pipe

    Is it ok to tie wrap the bath waste pipe to the bath cradle ( that connects the legs) . To give it extra support.
  9. X

    Screwing on bath cradle

    Is there a set distance from the end of the bath to were you screw on the 2 bath cradles that the legs attach to?
  10. X

    samll dent on copper water pipe

    Does a small dent on a 15mm copper water pipe need cutting out and replacing?
  11. X

    Is solvent weld cleaner needed

    is solvent weld cleaner needed before gluing on a strap on boss
  12. X

    Bent pan connectors

    If using a bent pan connector to connect to a 4insoil running at 90 degrees to the toilet is it best to not cut the bent pan connector down and cut the soil pipe. Or the other way around. Or does it make no difference?
  13. X

    Choice of inhibitor

    Is the much difference in the different central heating inhibitors on the market? Bought one from a plumbers merchants called instinct 100 it says its made by scalemaster.
  14. X

    leaking pushfit fitting

    Hey a pushfit watse fitting has started leaking after being knocked even though the fitting is all the way on why would this be?
  15. X

    end feed crossover

    are this ok to use on cold water pipework. Do must people use them instead of bending yourself? http://www.screwfix.com/p/flomasta-end-feed-crossover-part-15mm/84244
  16. X

    12,000 btus

    If putting a heating system in the system only has 23btus on it. But after picking up 3 rads. I have 3 more rads to pick up. That require 12000 btus of heat between them. Lounge a bedroom and the hall. I knew it says 15mm pipe will do 15,000 btus. But I am tempted to keep the run in 22mm till...
  17. X

    service valves on mixer showers

    Do you need to fit service valves on mixer showers. It's just the way they are usually piped up on new builds pipes dropping down in a stub wall to connect to the pipework under the floor there isn't really anywhere to put any. No exposed pipework
  18. X

    Pipe chased in party wall

    Is it ok to chase a gas pipe in to a party wall?
  19. X

    Shower above bath

    Hi I am looking at installing a shower above my bath as part of a bathroom re-fit. The options I have is; No.1 chase two copper pipes in to the wall elbow out above the bath and install a bar shower over the bath. No.2 Have a thermostatic bath shower mixer tap ( Think these are quite...
  20. X

    Window in shower area

    Hey is there any problem of having a window (frosted). In the showering area above the bath the window will all be tiled, it isn't at the minute. its a upvc window so no wood. T