It was connected behind.There seems to be an unused wire on the LHS.
No need for it?
As you say, very interesting. Do we know for sure that that Treaty is still 'active'?This is interesting with regard to John's earlier question re. the U.K. leaving the E.U. - if it happens.
I wouldn't say that being TT precludes the need for CPCs - should I perhaps remove (or at least disconnect) all of the CPCs in my (TT) installation?Shall I pretend the circuits without CPC are TT?
There's only one remaining circuit - the kitchen sockets, and no, I don't want one.
That was somewhat tongue-in-cheek but I do think it is going that way.Is that also relating to your mentioning that BS7671 is OTT?
Yes mine. I am quite happy with ADS.Are kitchen sockets not RCBO/RCD protected because their earthed, or for some other reason.
I believe it's actually ('borrowed') TN-C-SJohn. If you didn't have your TN-S through the pipes, then surely, if 100Ω or whatever is all you have, you may as well.
Yes, I realise that.I believe it's actually ('borrowed') TN-C-S![]()
No, but if all you had was a 100Ω earth which is not effective for ADS then CPCs aren't much use, are they?are you perhaps postulating trying to make the entire building an earth-free zone (which would obviously require there to be no extraneous-c-ps)?