• Looking for a smarter way to manage your heating this winter? We’ve been testing the new Aqara Radiator Thermostat W600 to see how quiet, accurate and easy it is to use around the home. Click here read our review.

fault

  1. J

    330+ not heating - no fault on display, pressure 0.9bar

    Hi - would be grateful for any help with the below (can't get British Gas out), Summary: 330+ boiler does not seem to be heating, despite HIVE telling me it is heating. Pressure reads 0.9bar on display. All the hive devices seem to be on and communicating. I think there's a problem with the...
  2. K

    Glowworm 30cxi repressure leak

    Hi, When running a bath this evening, the hot water went cold and when going to the boiler it was flashing red. So when opening the pressure valve, water came out of another area of the boiler (see video) and did not make any difference to the situation. Please let me know if there is...
  3. eveares

    Pyronix Enforcer Panel - SMS call Fail

    The other day for the first time in 4 years, my Pyronix Enforcer Home Control+ panel started beeping and went into a fault condition for the first time under a normal idle state. The error what I believe caused the "fault condition" was a "SMS call Fail" event, although not sure why it...
  4. G

    Ford focus potential alternator issue

    Hi all, Currently having some battery issues with my ford focus. The battery light will come on after a while of driving and eventually the battery died while i was driving when i had to brake. i went to halfords and they replaced my battery for free and the car was fine for a couple of long...
  5. K

    Yale Control Panel Alarm CONSTANT alarm!

    Hello there, First time poster been driven to the site by a constant alarm notification going off in our home! 10 days ago now, my family were woken by a distant (but very noticeable) alarm noise. Not like a house alarm where decibels are high, more a constant repetition Pip Pip...Pip Pip Pip...
  6. Daniel89

    Pyronix Enforcer

    Hi team, I’m a fire alarm engineer and have tried to branch into a bit of security stuff in my own house. So far it’s not going brilliantly. I’ve installed a wireless pyronix enforcer kit. Delta bell/4 pirs/1 door contact/1 wireless keypad and a couple of remote fobs. Install went well. But...
  7. B

    Telecom premier fault chirp

    Hi all!! I have a smartcom, premier elite 24, and my broadband has been down for 4 days now, intermittently coming back up with a fix ETA of another few days. Is there any way to disable fault chirp via RKP to avoid it bleeping at ridiculous o clock in the morning? I have a RKP in my bedroom ...
  8. D

    Samsung American fridge freezer

    Hi I have an american fridge freezer model RS53K4400SA s/n 051x4ebha00993m bought from curry a couple of years ago. It has developed a fault No lights no display no chill freeze or water. If switched off for a short period I can hear something power up when switched back on all fuses are fine...
  9. B

    Help required in resetting Eurosec

    Hello To all, Recently I bought a house . The alarm type is Eurosec ( I believe it is CP8L) The previous owner mentioned that they never used this alarm and they forgot the code. The display shows "Mains Flt" I don't know what this means, Is there anyway to make this alarm working. Please help me.
  10. Scoinsey92

    Mira Advance ATL Thermostatic shower cutting out

    Hi all, I'll start by saying that I'm not a plumber/electrician so I don't know which category this falls under as I don't even know what the problem is. Anyway... I've got a Mira Advance ATL Thermostatic Shower. It's roughly 3-4 years old. My memory fails me. However, last week it started...
  11. eveares

    Silly Electrical Mishap!

    So I am at my grandparents in Maidstone installing a Wireless Pyronix alarm in their bungalow. To run power to the panel, I take a 1mm² T&E from a junction box in the loft (what is on one of the lighting circuits) to the FCU and then to the Pyronix panel. First check for power at the panel and...
  12. A

    Brushless alternator fault

    Hi folks, Not been on here for a few years. see some familiar names though. Can anyone help me troubleshoot a 3.5 KVa capacitor regulated brushless alternator? It produces almost no voltage on the outputs (about 4 Vac open circuit at stator winding) So far I have: 1: checked the excitation...
  13. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    Have a Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen (photo below). No hot water for anything. Manual gives no indication. Photo of serial number below. Anyone ideas? I gather the "1304" means it was manufactured in 2013 on the 4th week of the year.
  14. C

    Vaillant EcoMax 835/2 f25 and f32 faults

    Hi, Have bought a house and inherited a Vaillant EcoMax 835/2 boiler, about 10 years old. Seemed to be working at first. However it started to give f25 faults and now alternates between f25 and f32. You can clear the fault and then it might work, but sometimes it takes 3/4 attempts. When set...
  15. R

    ferroli optimax he 26c

    Hi, I'm getting a F05 fault and been trying to diagnose..... Rang feroli and they've talked me through checking a few settings in the service menu, to which has not proven to work, this then leaves a replacement PCB....? Seen re-conditioned ones one ebay for £60, although a bit apprehensive...
  16. PhotographyJosh

    Galaxy MK7 keyprox on G2-20

    Hi, I'm having a problem with one of my keyprox modules (address 1), when I went out earlier on I used it to full set via pin number, when I came home again it wouldn't respond to a fob to unset or accept a pin, subsequently the alarm triggered and had to be unset from a second keypad (address...
  17. E

    What's wrong with our window?

    I'm hoping someone can help us. Our upvc window frame is lifting up off th windowsill. Does anyone know why this might be happening? We've just sold our house and are trying to get everything in order before we move. I've attached a photo of the problem. Any help is much appreciated. Thank you...
  18. Z

    Main combo 30 eco flashing hot water light

    the boiler fully works but every few hours the hot water light will start flashing and the boiler sounds like it's working, but there is no hot water running I have to reset the boiler to stop it doing this Does anyone know what this is? Thanks
  19. L

    baxi 105e changed pump still got a pump fault showing

    hi, firstly a bit of back ground. a couple of weeks ago the hot water pipe under our both blew off (due to the chap who fitted the bathroom before we bought the house not tightening a compression fitting properly) anyway this led to the hot water pumping out under the bath for around 20 mins...
  20. F

    Ideal evo he 22/24 fault

    hey guys, Could i get some advice on a issue i think iv diagnosed but need confirmation. I have a ideal evo he which keeps getting the El faults code on the screen. It does not happen all the time and might not happen for weeks than again it might happen twice in a day. Once reset it works...
Back
Top